Home > Buying  Leads > Multi-Parameter Patient Monitor PM8000
Multi-Parameter Patient Monitor PM8000

Send Inquiry  |   Add to Favorites  |   Print

  Product Name: Multi-Parameter Patient Monitor PM8000
  Product Categories: Medical devices/Cardiac Electrophysiology & Monitoring Devices
  Post Date: Jan 31,2013
  Description: Accessories: 1 pc 5 lead ECG Cable, snap, Defib, IEC, 3.5m, reusable - 30 pcs ECG Electrodes, adult, disposable - 1 pc SPO2 Finger Sensor, adult, 2.5m, reusable - 1 pc NIBP Cuff, Adult, 25cm-35cm, reusable - 1 pc NIBP Tube, 3m - 1pc Temperature Probe Skin, adult, 3m, reusable - 1pc Power Cord (EUR standard) - 1pc Rechargeable Lithium-Ion Battery (14.8V, 2100mAh) - 1 pc Ground Cable. Technical features Physical specification:Device Dimension: 320 mm(L)x150mm(W)x265mm(H)Weight: approx. 5kgDisplay:Colour TFT LCD: 10,1”– 12,1” Resolution: 800x600 Traces displayed: Up to 8Waveforms displayed: Up to 11Sweep Speed: 6.25, 12.5, 25, 50 mm/sECG:Lead Type: 5-lead and 3-lead selectableGain: Auto, x 0.125, x 0.25, x 0.5, x 1, x 2, x 4Sweep Speed: 6.25, 12.5, 25, 50 mm/sECG HR Range:Adult: 15~300bpmPediatric/Neonate: 15~350bpmResolution: 1 bpmAccuracy: ±1 bpm or ±1% (whichever is greater)Filter:Diagnostic Mode: 0.05~150 HzMonitoring Mode: 0.5~40 HzSurgical Mode: 1~20 HzST-Segment Detection:Measurement Range: -2.0 mV~2.0 mVAlarm Range: -2.0 mV~2.0 mVRESPMethod: Trans-thoracic impedanceOperation Mode: Auto/ManualRR Measurement Range:Adult:0~120 rpmNeonate/Pediatric: 0~150 rpmResolution: 1 rpmApnea Alarm Thresold: 10,15,20,25,30,35,40 sBand Width: 0.2-2.5 Hz (-3 dB)Sweep Speed: 6.25, 12.5, 25, 50 mm/sSPo2Measurement & Alarm Range: 0~100% (SpO2)Resolution: 1%Accuracy: ±2% (70~100% Adult/Pediatric)±3% (70~100% Neonate)PR Measurement: 25~300 bpmResolution: 1bpmRefresh Rate: 1 secondNIBPMethod: Automatic OscillometricOperation Modes: Manual/Automatic/ContinuousAuto Measurement Time Interval:1,2,3,4,5,10,15,30,60,90,120,240,480 minutesMeasurement Unit: mmHg/kPaMeasurement Types: Systolic, Diastolic, MeanPressure Range:Adults: Systolic: 40~270 mmHg Diastolic: 10~215 mmHg Mean: 20~235 mmHgPediatrics: Systolic: 40~200 mmHg Diastolic: 10~150 mmHg Mean: 20~165 mmHgNeonates:Systolic: 40~135 mmHg Diastolic: 10~100 mmHg Mean: 20~110 mmHgResolution: 1 mmHgAccuracy:Max Mean error: ±5 mmHgMax Standard Deviation: 8 mmHgPR from NIBP Measurement Range: 40~240 bpmResolution: 1bpmAccuracy: 3 bpm or 3.5% (whichever is greater)SP10:2002Temperature (2 Channels, 1 probe by default)Measurement/Alarm Range: 0~50C° (32-122 F°)Resolution: 0.1 C°Accuracy: ±0.1 C° (without probe)Channel: Dual-Channel- Provide T1; T2; ?TPower Supply: AC Power: 100~240 V AC, 50/60 HzBattery: 14.8 V Rechargeable Li-ion Battery IBP (2 Channels)Measurement Pressure: ART, PA, CVP, RAP, LAP,ICP, P1,P2Measurement Range: -50~300 mmHgResolution: 1 mmHgAccuracy: ±2% or ±1 mmHg (whichever is greater, without probe)Sensitivity: 5 ?V/V/mmHgImpedance Range: 300~3000? Philips Respironics CO2Type: Sidestream/MainstreamRange: 0~150 mmHgAccuracy: ±2 % - 0~40 mmHg±5% - 41~70 mmHg±8% - 71~100 mmHg±10% - 101~150 mmHgAwRR Accuracy: ±1 rp
With Printer Max 6Kg
Price for 43 Pz.
  Email: media.san.bg@gmail.c

Disclaimer statement:The information and data included above have been realized by the enterprises and compiled by Department staff, and are subject to change without notice to you. Chinamedevice.com makes no warranties or representations whatsoever regarding the facticity, accuracy and validity of such information and data. Our suggestion: In order to ensure your interest, we suggest registering as our gold suppliers.
Please send your Inquiry here:* is required.
Subject: *
Message: *
Company Name:
Contact: *
Tel: *
(Type: +86-571-88228426)
Fax:
Email: *
Zip:
Address:
CheckCode:      *