Home > Selling Leads > C600 Color Doppler Ultrasound System (Touch Screen)
- C600 Color Doppler Ultrasound System (Touch Screen)(China)
-
Send Inquiry |
Add to Favorites |
Print
Product Name: C600 Color Doppler Ultrasound System (Touch Screen) Product Categories: Medical devices/Diagnostic Devices Post Date: Jul 27,2016 Expiry Date: Jan 26,2016 Description: Payment Method: TT
NEUTRAL PACKING: baichengmt
Feature:
-22 inch color LED Touch Screen
-With multiple probes to fit different uses and budgets
-Imaging Mode: B, BB, M, CD, PWD, CWD, DirPwr, Pwr
-High Definition Multiple Color Doppler mode imaging,
include supports most Doppler imaging and advanced imaging
processing for cardiac, vascular access, and OB diagnostics.
-Can be equipped in addition with 3D and panoramic image
processing for volume reconstruction, visualization,
segmentation, and measurement.
-Can install and run all applications with Microsoft?
Windows? including patient management systems for better
follow up, as well as network tools to access PACS data
-Large volume store and preview, edit records (image, voice
comments, cineloop video) by hardisk, USB flash disk, DVD
-Triplex Display: Real-time triplex display B/ Color
Doppler/ Pulsed Spectral Doppler (Three TGCs can be
adjusted respectively)
-THI (Tissue Harmonic Imaging) technology: Suppress speckle
noise, brighten image and improve the image quality
-One-key Optimization: One key for eight-parameter
adjustment, easy image optimization.
-Powerful Measurement Software: Versatile clinic-oriented
measuring software package
-Image Management: Versatile image format/ large capacity
cineloop storage/ preview/ edit
-Can maintain and update by internet
-Space saving by the integration of color doppler
ultrasound scanner and office computer, and can either lay
on a desk or be wall mounted.
-Can be controlled either through a regular PC keyboard and
a mouse, or a dedicated ultrasound keyboard.
-Except general use, special suit for use in operation room
or ambulances
-2 probe sockets
Imaging Modes
· B
· B+B
· 4B
· B+M
· M
· B-steer
· Compound + Trapezoid
· Color Doppler (CFM)
· Power Doppler (PDI)
· Directional Power Doppler (DPDI)
· Pulsed Wave Doppler (PWD)
· B+PWD (Duplex)
· B+CFM/PDI/DPDI+PWD (Triplex)
· High Pulse Repetition Frequency (HPRF)
· Tissue Harmonic Imaging (THI)
Ultrasound imaging
· ultrasound image size: automatically adjustable
to screen resolution
· gray scale: 256
· color scale: 256
· full motion and full size real-time ultrasound
imaging, up to 120 fps (depends on selected scan depth,
scan angle, focus mode, High Line Density setting, computer
speed)
· cineloop recording/play: several thousands frames
(depends on computer memory size and scan mode)
· zoom mode: from 60% to 600% in all modes (Scan,
Freeze, B, B+B, 4B, Doppler modes, M-zoom, cineloop and etc)
· viewing area variable for frame rate maximizing:
6 steps
· thumbnail mode: up to 32 images
· "Freeze" mode
· "Auto Freeze" mode
Scanning Method
· electronic linear
· electronic convex
· electronic microconvex
· scanning depth: 2-30 cm
Transducers
· convex, micro-convex, linear, transvaginal
. from 2,0 MHz to 12,0 MHz
. multifrequency
· automatic transducer recognition
Color Doppler
· PRF variable: 0.5-10 kHz
· wall filter settings: 3 steps (5%, %10%, 15% PRF)
· gain control: 50 dB
· angle steering for linear transducers: ±10°
· real-time spatial filter: 4 values
· CFM palette: 10 maps
· PDI palette: 11 maps
· B/Color priority control
· color threshold control
· CFM baseline control
· Doppler frequency selection: 2 frequencies / each
transducer
· color frame averaging: 8 values
· Transparent Color Mapping (TCM): 10 values
Automatic Image Optimization
· single click auto adjustment:
. B-image: gain, dynamic range, TGC sliders
. Color Doppler: CFM/PDI/DPDI gain
. Pulsed Waved Doppler: baseline, invert, PRF
Pulsed Wave Doppler
· PRF variable: 1-15 kHz
· wall filter settings: 16 steps (2.5%-20% PRF)
· gain control: 50 dB
· angle steering for linear transducers: ±10°
· real-time trace line with automatic calculation
of spectrum parameters
· stereo sound: volume control
· PWD palette: 12 maps
· Doppler frequency selection: 2 frequencies / each
transducer
Focusing
digital transmit focusing
multi focus mode:
transmit/receive focusing
programmable focus area presets
dynamic focus mode:
transmit variable focus
dynamic receive focus
Processing
High Line Density scan mode for better resolution
TGC Control, 5-10 sliders (customizable) 40 dB
dynamic range: 120 dB, 8 values
overall gain control
M - mode sweep speed control
acoustic power control
variable frame averaging
brightness, contrast
advanced gamma control: 8 fixed curves, 8 user defined
(custom)
scan direction, rotation, up-down controls
negative / positive control
bi-linear interpolation
echo enhancement control
noise rejection function
speckle reduction and structure improvement PureView: 8
algorithms
Functions
mouse / trackball / keyboard operation
anatomical icons with transducer position indicator
direct e-mail sending with image or video attachment via
Internet
DICOM file push to server
printing on system printer
unlimited programmable presets for clinically specific
imaging
TV output via computer display adapter
File Formats
image and video save / load
AVI
JPG
BMP
PNG
TIF
DCM (DICOM uncompressed)
DCM (DICOM-JPEG RGB/YBR)
DCM (DICOM-JPEG RGB/YBR Video)
TPD (Picture Data)
TVD (Video Data)
DICOM
Verification SCU
Modality Worklist (MWL) SCU
Modality Performed Procedure Step (MPPS) SCU
Store SCU (images, cines)
Print SCU (grayscale, color)
Interface Customization
the set of predefined skin schemes for software interface
the set of predefined buttons images
Multilanguage support, languages:
Chinese
English
German
Italian
Korean
Lithuanian
Magyar
Polish
Romanian
Russian
Spanish
B+M, B+PW layout position, size
ultrasound area size
font size
General Measurements and Calculations
B and Color Doppler mode general measurements and
calculations
Distance
Length (method: 1 trace)
Area, Circumference (methods: 1 ellipse, 1 trace, 1
distance)
Volume (methods: 1 distance, 2 distances, 3 distances, 1
ellipse)
Angle (methods: 2 distances, 3 distances)
Stenosis % (methods: 2 distances, 2 ellipse or trace areas)
A/B Ratio (methods: 2 distances, 2 ellipse or trace areas,
2 ellipse or trace circumferences)
M mode general measurements and calculations
Distance, Time, Velocity
Heart Rate (methods: 1 beat, 2 beats)
Stenosis % (method: 2 distances)
A/B Ratio (methods: 2 distances, 2 times, 2 velocities)
PW mode general measurements and calculations
One-point PW measurements and calculations:
Velocity
Pressure Gradient (PG)
Two-points PW measurements and calculations:
Velocities difference
Pressure Gradients (PG) difference
Time interval
Acceleration
Resistivity Index (RI)
Heart Rate (methods: 1 beat, 2 beats)
Velocity minimum and maximum
Pressure Gradient (PG) minimum and maximum
Trace-based PW measurements and calculations:
Trace Time
Trace Velocity min, max, mean
Trace Pressure Gradient (PG) min, max, mean
Velocity Time Integral (VTI)
Pulsatility Index (PI)
A/B Ratios of one-point PW measurements:
Velocities A/B Ratio
Pressure Gradients (PG) A/B Ratio
A/B Ratios of two-point PW measurements:
Velocity differences A/B Ratio
Pressure Gradient (PG) differences A/B Ratio
Time differences A/B Ratio
Accelerations A/B Ratio
Resistivity Indexes A/B Ratio
A/B Ratios of trace-based PW measurements:
Velocity means A/B Ratio
Pressure Gradient (PG) means A/B Ratio
Pulsatility Indexes A/B Ratio
Velocity Time Integrals A/B Ratio
PW mode Human Cardiology measurements and calculations
Left Ventricle: LVOT Diam, LVOT VTI, LVOT Vmax, SV (Stroke
Volume), SI (Stroke Volume Index), CO (Cardiac Output), CI
(Cardiac Index), dP:dt (Delta Pressure : Delta Time), MPI
(Left Ventricle Myocardial Performance Index)
Mitral Valve: MVA(PHT) (Mitral Valve Area using Pressure
Half Time), MVA using Continuity Equation (LVOT Diam, MV
VTI; LVOT Diam, MV Vmax), dP:dt, E/A ratio
Aortic Valve: AVA (Aortic Valve Area) using Continuity
Equation (LVOT Diam, AV VTI; LVOT Diam, AV Vmax), AVI
(Aortic Valve Index), DPI (Dimensionless Performance
Index), AV PHT (Aortic Valve Pressure Half Time)
Right Ventricle: RVOT Diam, RVOT VTI, RVOT Vmax, dP:dt, RV
MPI (Right Ventricle Myocardial Performance Index), MPAP
(Mean Pulmonary Artery Pressure)
Tricuspid Valve: TVA (Tricuspid Valve Area) using
Continuity Equation (RVOT Diam, TV VTI; RVOT Diam, TV
Vmax); TV E/A ratio, TV PHT
Pulmonic Valve: PVA (Pulmonic Valve Area) using Continuity
Equation (RVOT Diam, PV VTI; RVOT Diam, PV Vmax), PVI
(Pulmonic Valve Index), DPI (Dimensionless Performance
Index), PV PHT (Pulmonic Valve Pressure Half Time)
Pulmonary Vein; Hepatic Vein
Shunts: Qp:Qs (Pulmonary-Systemic Flow Ratio)
Human Measurements and Calculations Packages
Human General calculations package
Measurements: the same as general measurements of different
modes (B, M, PW)
Calculations: BSA via Height and Weight, BSA via Weight,
Hip Angles (α, β), Femoral Head Coverage (FHC)
PW mode calculations: HR, SV using Flow Area, SV using Flow
Diameter, SI, CO, CI, Area calculation using Continuity
Equation (methods: Area and VTI, Area and Velocity,
Diameter and VTI, Diameter and Velocity, Velocity Ratio
(S/D, D/S), dP:dt, Flow Volume (methods: Diameter, Area),
PHT, MVA
Human Obstetrics / Gynecology (OB / GYN) calculations
package
Measurements: LMP (entered or from calendar), AC, BPD, FL,
HC, FTA, AAPD, ATD, TAPD, TTD, CRL, GS, HL, TL, UL, OFD,
BOD, Cereb, Clav, Rad, AFI, FHR
Estimated date of birth (EDD) calculations: EDD(LMP), EDD
(GA), EDD(AUA)
Ratios: FL / AC, FL / HC, FL / BPD, HC / AC, CI
Estimated Fetal Weight (EFW) calculations: EFW(AC), EFW
(AC,BPD), EFW(AC,FL), EFW(AC,HC), EFW(AC,HC,BPD), EFW(FL),
EFW(AC,FL,HC), EFW(AC,BPD,FL), EFW(AC,BPD,FL,HC), EFW
(BPD,FL,FTA), EFW(BPD,ATD), EFW(BPD,TTD), EFW
(BPD,TAPD,TTD), EFW(BPD,FL,TAPD,TTD)
Selected EFW values are used for calculation of Average EFW
Gestational Age (GA) calculations: GA(AC), GA(BPD), GA
(CRL), GA(FL), GA(GS), GA(HC), GA(HL), GA(OFD), GA(TL), GA
(UL), GA(HC/AC), GA(FTA),GA(ATD), GA(TAPD), GA(TTD), GA
(BOD), GA(Cereb), GA(Clav)
Fetal Growth estimation (trending): AC(GA), BPD(GA), CRL
(GA), FL(GA), GS(GA), HC(GA), HL(GA), OFD(GA), TL(GA), UL
(GA), [FL/AC](GA), [FL/HC](GA), [HC/AC](GA), EFW(GA), AAPD
(GA), ATD(GA), TAPD(GA), TTD(GA), BOD(GA), Cereb(GA), Rad
(GA), Clav(GA), AFI(GA), FHR(GA)
Selected Growth Tables are visualized as Fetal Growth Curves
Software supports unlimited number of user-defined Growth
Tables
Human Gynecology (GYN)
Measurements: length, height, width of uterus, cervix,
ovaries, renals, follicles
Calculations: volumes of uterus, cervix, ovaries, renals,
follicles
Human Abdominal exam measurements and calculations
Liver: Volume (CC, AP, LL diameters)
Gallbladder: Volume, Wall Thickness, Extrahepatic Bile Duct
(EBD), Common Bile Duct (CBD), Common Hepatic Duct (CHD)
Pancreas: Head Diameter, Body Diameter, Tail Diameter,
Pancreatic Duct Head, Pancreatic Duct Body
Spleen: Volume (length, width, thickness)
Gastrointestinal Tract: Appendix Wall Thickness, Appendix
Diameter, Bowel Wall Thickness (at Stomach, Small Bowel,
Large Bowel)
Urinary Bladder: Volume (length, height, width)
Right / Left Kidney: Volume (length, height, width), Pelvis
Diameter
Human Urology
Measurements: length, height, width of kidneys, bladder,
prostate, testes
Calculations: volumes of kidneys, bladder, prostate,
testes; RUV (Residual Urine Volume)
Human Endocrinology
Measurements: length, width, thickness of thyroid lobes
Calculations: volumes thyroid lobes; volume of thyroid
Human Vascular exam measurements and calculations
Distance and area -based stenosis calculations at left
(right) Subclavian, CCA (Common Carotid Artery), Bulb, ICA
(Internal Carotid Artery), ECA (External Carotid Artery),
Vertebral vessels at proximal, middle, distal locations
PSV/EDV (Peak Systole Velocity / End Diastole Velocity)
ratios for each vessel and location
Ratios of velocities ICA PSV/CCA PSV, ICA EDV/CCA EDV, ICA
PSV/CCA EDV, ECA PSV/CCA PSV, ECA EDV/CCA EDV, ECA PSV/CCA
EDV at Rt. (Lt.) Prox. (Mid., Dist.) locations
Human Cardiology
Software supports the following measurements of Left
Ventricle, Aortic Valve, Left Atrial: IVSd
(Interventricular Septal Thickness, diastole), LVIDd (Left
Ventricle Internal Diameter, diastole), LVPWd (Left
Ventricle Posterior Wall Thickness, diastole), AOd (Aortic
Root Dimension, diastole), IVSs (Interventricular Septal
Thickness, systole), LVIDs (Left Ventricle Internal
Diameter, systole), LVPWs (Left Ventricle Posterior Wall
Thickness, systole), LADs (Left Atrial Dimension, systole).
Calculations: HR (Heart Rate), BSA (Body surface Area),
Left ventricle volume (methods: Cubed, Teichholz, Gibson,
Simpson’s LVAM-LVAP, Simpson’s single plane, Simpson’s
biplane, Bullet, Ellipsoid single plane, Ellipsoid
biplane), SV (Stroke Volume), SI (Stroke Volume Index), EF
(Ejection Fraction), CO (Cardiac Output), CI (Cardiac
Index), STIVS (Interventricular Shortening), FS (Fractional
Shortening), STPW (Posterior Wall Shortening), LVM (Left
Ventricle Cardiac Mass), CMI (Cardiac Mass Index), LA/AO
Ratio
Human/Veterinary OB Gyn packages: software supports
unlimited number of user-defined GA tables, selected GA
values are used for calculation of Average GA (Average
Ultrasound Age - AUA).
Human/Veterinary Cardiology measurements package
automatically displays hint images that show where and how
appropriate measurements must be performed.
Veterinary Calculations Packages
Canine OB
Measurements: GS, CRL, HD, BD
Gestational Age (GA) calculations: GA(BD), GA(CRL), GA(GS),
GA(HD)
Feline OB
Measurements: HD, BD
Gestational Age (GA) calculations: GA(BD), GA(HD)
Ovine OB
Measurements: CRL
Gestational Age (GA) calculations: GA(CRL)
Bovine OB
Measurements: BD, CRL, HD, UD
Gestational Age (GA) calculations: GA(BD), GA(CRL), GA(HD),
GA(UD)
Veterinary Calculations Packages
Equine OB
Measurements: AOD, BPD, CRL, EOD, GS
Gestational Age (GA) calculations: GA(AOD), GA(BPD), GA
(CRL), GA(EOD), GA(GS)
Llama OB
Measurements: BPD
Gestational Age (GA) calculations: GA(BPD)
Goat OB
Measurements: BPD
Gestational Age (GA) calculations: GA(BPD) for different
species
Animal Cardiology
Left Ventricle, Aortic Valve, Left Atrial measurements:
IVSd, LVIDd, LVPWd, AOd, IVSs, LVIDs, LVPWs, LADs, ET
Calculations: HR, LV volume (Cubed, Teichholz, Gibson), SV,
EF, CO, STIVS, FS, STPW, LA/AO, VCF
Standard Configuration:
-Host 1 unit
-Convex probe 1 pcs
-Lienar or Trans-vaginal probe 1 pcs
-Computer keyboard 1 pcs
Company: B&C Medical Technology Co.Ltd [ China ] Address: Room 1505, 15/F, D Block, Wanda Plaza, Heping roadNo.58, Xuzhou Contact: Cherry Tel: 86-516-82509209 Mobile: 1315121342 Fax: 0(086)5168250-9209 Email: baichengmt_02@outlook.com Disclaimer statement:The information and data included above have been realized by the enterprises and compiled by Department staff, and are subject to change without notice to you. The ChinameDevice.com makes no warranties or representations whatsoever regarding the facticity, accuracy and validity of such information and data. Our suggestion: In order to ensure your interest, we suggest registering as our gold suppliers.
- See more selling leads from this Gold Supplier:
- Browse By Category
-
- Radiological Devices
- Intraocular, Cornea and Neuromaterials Implants
- General Surgery Devices
- Plastic & Reconstructive Surgery Devices
- Restorative Devices
- Anesthesiology and Respiratory Devices
- Interventional Cardiology Devices
- Pacing, Defibrillator and leads
- Gastroenterology and Renal Devices
- Ear, Nose and Throat Devices
- Cardiac Electrophysiology & Monitoring Devices
- Orthopedic Devices
- Obstetrics & Gynecology Devices
- Other Devices
- Peripheral Vascular Devices
- Infection Control Devices
- Physical Therapy devices
- Neurodiagnostic and Neurotherapeutic Devices
- Circulatory Support and Prosthetic Devices
- General Hospital Devices
- Urology and Lithotripsy Devices
- Dental Devices
- Diagnostic Devices