Gold Suppliers > Guangzhou Yueshen Import & Export Co.,Ltd > 500mA medical X-ray machine

500mA medical X-ray machine

500mA medical X-ray machine
  • Brand Name : Yueshen
  • Category : Others
  • Description :
  • Profile & Features

    1  Micro-compute control x-ray radiography assembles: optional 500mA.

    2  Total 540 storage combination controlled by element such as kV mA S is applied radiography for the following filed three body position, fat middle and thin body type, automatic detect and display cod of mistake in system, send warning signal, detect accuracy and maintain.

    3  X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protectorate provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.

    4  Radiography table can move lengthways and crossover, can loaded all kinds of radiography dark box, use conveniently and it is beautiful.

    5   Applied in all kinds of hospital for radiography such as general bodybeam filtrationand chest.

    Department

    Technology parameters

    High voltage generator control table and high voltage transform assemble

    Power

    Voltage

    380V±10%

    Capacity

    50Hz±1Hz

    Frequency

    ≥32KVA

    Inner resistance

    ≤0.3Ω

    Tube voltage

    45-125kV step 1kV

    Tube currency

    30-500mA 8 shift

    Exposure time

    0.01-5.0S 25 shift

    Max rated capacity

    mA

    600

    500

    400

    500

    400

    kV

    71

    84

    106

    84

    106

    X-ray assembly

    Type of x-ray

    XD52-30.50/125

    Focus

    1×1.2×2 double focal

    Rated rotate speed of anode

    2800r/min

    Manually beam limited device

    Model

    Manually continuous adjusted field of

    Field view

    View, luminosity≥100LX,1minlimit-time device

    CDG

    Multi function radiography table

    Moving table

    Lengthways

    ±600mm

    Electromagnetism locking

    Across

    ±120mm

    Mobile beam filtration grid

    Grid density

    28L/cm

    Grid ratio

    81

    Focusing distance

    100cm

    Scope of moving

    ≥600mm

    Radiography item

    5×7,8×10,10×12,11×14,

    12×15,14×14,14×17

    Distance from surface to film

    75mm

    Height of bed

    700mm

    Moving pillar

    ±180°,per 90°orientation, moving lengthways ≥1500mm

    Bulb tube

    Rotate the cross arm±180,ascend $ descend 1100mm

    Option

    LSJ pillar radiography frame

    The scope of ascend and descend

    1450mm

    The minimum distance from focal spot

    380mm

    Radiography item

    ×10 10×12 11×1412×15

    14×14 14×17

    Fixed beam filtration role

    Grid density

    40L/cm

    Grid radio

    10:1

    Focal distance

    180cm

Contact Info
Company: Guangzhou Yueshen Import & Export Co.,Ltd
Area: China/Guangdong
Contact: Ms. Nancy Yi
Tel: 86-20-34050120
Email: webmaster@medicalxray.com.cn
Fax: 86-20-34052048
Web site: http://www.medicalxray.com.cn
Add: Room D2001,Filmtown Garden,No.350 Middle Xin'gang Road
P.C.: 510310