Gold Suppliers > Guangzhou Yueshen Import & Export Co.,Ltd > Medical X-ray Machine of 200mA
Features:
Single diagnostic table and single X-ray tube with rotated anode
KVmA and a interlocking protection and radiograph time-limited protection are provided
Filament for stabilizing voltage, space charge compensation and anode starting-up protection device are provided
Voltage of power supply and KV with digital display can be adjusted constantly and respectively
It becomes convenient to install without above-ground railway and be operated easilly
Electromagnetism are provided for pillar lengthways, crosswise, and sleeve moving up and down
Frame:
Control Table, Diagnostic Table / Radiograph Device for Stomach and Intestine, High Voltage Transformer Assembly, High Voltage Cable, X-ray Tube Assembly
Technology Parameters
Description | Technology Parameters | |
Power Supply | Voltage | A.C.380V / 220V (±10%) |
Frequency | 50Hz ± 1Hz | |
Capacity | 20KVA | |
Power Supply Resistance | A.C.380V≤1.0Ω; A.C.220V≤0.3Ω | |
Maximum tube voltage | 120KV | |
Maximum tube currency | 200mA | |
Fluoroscopy | Tube voltage | 40110KV |
Tube currency | 0.55mA | |
Radiograph | Tube voltage | 40120KV |
Tube currency | Small Focus 50mA100mA; Big Focus100150200mA | |
Spot film | 100mA Small Focus | |
Time | 0.046.3s Divided into 23 grades from 0.046.3s | |
High Voltage Generator | Capacity | 20KVA |
X-ray Tube | Model | XD 512040 / 125 |
Focus | Small Focus 1×1mm2 Big Focus 2×2mm2 | |
Rotated Speed of anode | 2800r / min | |
Diagnostic Table | Scope of rotation | 90° 0°-5° |
Mobile beam filtration device | Grid density N=28 | |
Focus Distance f o>1000mm | ||
Grid Ratio r=8 | ||
Distance from surface to film | ≤60mm | |
Stomach & Intestine Radiograph Device | Spot film device specificationStomach & Intestine Radiograph | 127×178mm( 5× 7) binary picture |
203×254mm( 8×10) binary picture | ||
254×305mm(10×12) binary picture | ||
280×356mm(11×14) quartering picture | ||
Moving lengthways (along ground railway) | 1500mm | |
Moving crosswise (left & right) | 740mm | |
Moving up and down | 700mm 1900mm | |
Way of locking | Electromagnetism locking | |
Beam Limited Device | Manually single automatic multi-optional |