Home > Selling Leads > SP-2102UV/UVPC Visible Spectrophotometer
- SP-2102UV/UVPC Visible Spectrophotometer(Zhejiang)
-
Send Inquiry |
Add to Favorites |
Print
Product Name: SP-2102UV/UVPC Visible Spectrophotometer Product Categories: Laboratory Equipment Post Date: Dec 14,2011 Expiry Date: Dec 13,2012 Description: Payment Method: T/T,L/C
Switchable spectral bandwidth especially suits for the
analysis in drug control, pharmaceutics, and scientific
research, and so on.
SP-2102UVPC spectrophotometer has been developed on the
basis of SP-2102UV, which utilizes the abundant resources
and functions of MS Windows platform. SP-2102UVPC is a new
generation of UV/Vis Spectrophotometer with spectrum
scanning function.
This model not only reaches the instrument technical index
prescribed in Drug Codex, but also has a good many
quantification and qualification functions, such as
wavelength scanning, single wavelength, double wavelength,
triple wavelength, or multiple wavelength measurement, as
well as derivative spectrum analysis, four basic
calculations of spectra.
Excellent instrument stability and sensitivity render
itself to be the top one among the same class instruments.
The performance of SP-2102UVPC competes that of double
beams spectrophotometers.
▲Performance Specification
MODEL
SP-2102UV
SP-2102UVPC
Optic system
Littrow type optic system with 1200 grooves/mm diffraction
grating monochromator.
Light path
100mm
Spectrum band width
2nm
Wavelength range
190-1100nm
Wavelength accuracy
±1nm
±0.5nm
Wavelength repeatability
0.5nm
0.2nm
Stray light
≤0.1%T (at 220nm & 340nm)
Photometric Mode
T, A, and C measurement
Photometric Range
0-125.0%T, -0.097-3.000A
Photometric accuracy
±0.3%T
Photometric repeatability
0.15%T
Stability
±0.001A/hr (at 500nm, after warming up for 1 hour)
Baseline flatness
±0.002A
▲Main Specification
Display
2*20 characters LCD with blacklight function(SP-2102UV)
128*64 LCD Displayer (SP-2102UVPC)
Light Source
6V10W Halogen Lamp(2000 hours)
Deuterium lamp(1000 hours)
Sample Compartment
100mm Optical Path
Standard Cell Holder
10mm
Standard Cell Configuration
10mm Glass cell(4pcs)
Power Requirement
110/220VAC,50/60Hz,±10%
▲Basic testing mode
Basic measurement
Photometric measurement,(A/T)
Concentration measurement (C )
Concentration measurement
Slope method (C=K*A)
Standard curve method (C=K*A+b)
Software functions
Win-spec workstation, SP-2.33EN
Photometric analysis
T, A, and C measurement
Quantitative analysis
Standard curve measurement
Kinetic analysis
Measurement with time-scanning
Spectrum scan analysis
Spectrum scan function
▲Basic instrument functions
Storage function
56 standard curves
100%T or 0%T setup
Automatic
System self-testing
Wavelength self-testing, light soures self-testing,filter
switching, energy calibrating.
Light source switching
The switching point can be set at any position at the
wavelength range of 325-355nm to improve testing accuracy.
Light source management
Light source on/off status can be controlled to elongate
its working life.
Signal output
RS-232C, Analog
Communication function
Intercommunication can be realized after connecting to PC
▲Extended function (Accessories or workstation software
should be chosen.)
Automatic multi-cells holder
Auto-sorting or manual-sorting test, 4 cells and 6 cells
for choice.
Micro-volume testing
100μl, as the minimum volume. (Special cell holder and
cuvette should be used.)
Constant temperature testing
Testing samples under the condition of constant
temperature. This function is especially suit for kinetic
analysis. Electronic constant temperature accessory or
water cycling constant temperature accessory should be
chosen.
USB communication
USB Port for choice, which fits the developmental tide of
modern computer.
Standard configuration
10mm manual four-cell holder, 1pcs
10*10*45 mm standard glass cuvettes, 4pcs
10*10*45 mm standard quartz cuvettes, 2pcs
RS-232C connection cord, 1pcs
Power cable, 1pcs
User manual, 1pcs
Operating protocol, 1pcs
Win-spec software 2.33EN, 1pcs
Multiple wavelength analysis
Up to 20 wavelength points can be used for measuring
sample's absorbance or transmittance. The background can be
corrected by multiple wavelengths calculation to measure
unknown samples, which great ly enhance test precision and
speed. Besides, by inputting K factor, user can do multiple
wavelengths programming to measure the concentration of
unknowns.
Note: There may not be special notifications when the
technical specification,profile and configuration changed.
Please, the products will
be in agreement with the real models.
Company: Ningbo Biocotek Scientific Instrument Co.,Limited [ Zhejiang ] Address: Room 1112,Jinmao Building,West Mingzhou Road,Beilun,Ningbo,China Contact: wendy Tel: 0574-86834692 Mobile: Fax: 0574-86834693 Email: wendy@biocotek.com Disclaimer statement:The information and data included above have been realized by the enterprises and compiled by Department staff, and are subject to change without notice to you. The ChinameDevice.com makes no warranties or representations whatsoever regarding the facticity, accuracy and validity of such information and data. Our suggestion: In order to ensure your interest, we suggest registering as our gold suppliers.
- See more selling leads from this Gold Supplier:
- Browse By Category
-
- Restorative Devices
- Ear, Nose and Throat Devices
- Intraocular, Cornea and Neuromaterials Implants
- Other Devices
- Pacing, Defibrillator and leads
- Cardiac Electrophysiology & Monitoring Devices
- Orthopedic Devices
- Neurodiagnostic and Neurotherapeutic Devices
- Plastic & Reconstructive Surgery Devices
- Dental Devices
- Diagnostic Devices
- Obstetrics & Gynecology Devices
- Gastroenterology and Renal Devices
- Interventional Cardiology Devices
- Peripheral Vascular Devices
- Radiological Devices
- Infection Control Devices
- Urology and Lithotripsy Devices
- Anesthesiology and Respiratory Devices
- General Hospital Devices
- Physical Therapy devices
- Circulatory Support and Prosthetic Devices
- General Surgery Devices