Product Name: Cardiac Troponin I Fast Test Kit Product Categories: Medical Equipment Manufacturing Equipment Post Date: Jan 08,2013 Expiry Date: Jan 08,2014 Description: Payment Method: T/T L/C
Intended Use:
Cardiac Troponin I Fast Test Kit applies colloidal gold
immunochromatography to detect cardiac Troponin I
(cTnI) in serum and plasma samples semi-quantitatively or
quantitatively. This test is used as an aid in the
diagnosis of Myocardial Infarction such as Acute
Myocardial Infarction, Unstable Angina, Acute
Myocarditis,
and Acute Coronary Syndrome.
Principle of the Procedure:
The test kit contains two high specific and sensitive anti-
human cardiac Troponin I monoclonal antibodies:
one gold-labelled and coated on the polyester film, the
other biotinylated and fixed on the test line of the
product. The antibodies form sandwich complexes with any
cTnI that is present in the blood sample. The
sample passes through the detection zone, in which the
cTnI sandwich complexes gather along a line,
appearing as a purplish red streak (the test or signal
line). Excess gold-labelled antibodies gather along
the control line, signalling visually that the test is
valid. The intensity of the test line increases in
proportion
to the cardiac Troponin I concentration.
Test Procedure:
1. Please read the manual carefully before testing,
restore the samples and the test card to room temperature
and number the samples.
2. Remove the test card from bag, and use it within 1
hour. (The test card should be used as quickly as
possible once the bag is opened, especially if the room
temperature is over 30 °C and the humidity is over 60%).
3. Put the test card on a clean table, horizontally layed
and tagged.
4. Vertically dropping 120 μl or 3 to 4 drops of samples
to the sample port on the test card.
5. Referring to the standard colorimetric card, get the
semi-quantitative result by eye, or read the quantitative
result with the matching equipment. The result must be
read within 10~30 mins.
Warnings and Precautions:
1. Pipettes can be used for one specimen only in order to
avoid cross-contamination.
2. The best testing temperature is 15~30 C, and the best
humidity is 40~60%.
3. Patient samples, used test card and transfer pipettes
may be potentially infectious. Proper handling and
disposal methods should be established by the laboratory
direction in accordance with local regulations.
Company: Getein Biotechnology Co., Ltd. [ Jiangsu ] Address: No.9 Bofu Road,Luhe District,Nanjing,211505,China Contact: Fiona Tel: +86-25-68576663 Mobile: Fax: Email: per.service003@hotmail.com Disclaimer statement:The information and data included above have been realized by the enterprises and compiled by Department staff, and are subject to change without notice to you. The ChinameDevice.com makes no warranties or representations whatsoever regarding the facticity, accuracy and validity of such information and data. Our suggestion: In order to ensure your interest, we suggest registering as our gold suppliers.
- See more selling leads from this Gold Supplier:
- Browse By Category
-
- Restorative Devices
- Ear, Nose and Throat Devices
- Intraocular, Cornea and Neuromaterials Implants
- Other Devices
- Pacing, Defibrillator and leads
- Cardiac Electrophysiology & Monitoring Devices
- Orthopedic Devices
- Neurodiagnostic and Neurotherapeutic Devices
- Plastic & Reconstructive Surgery Devices
- Dental Devices
- Diagnostic Devices
- Obstetrics & Gynecology Devices
- Gastroenterology and Renal Devices
- Interventional Cardiology Devices
- Peripheral Vascular Devices
- Radiological Devices
- Infection Control Devices
- Urology and Lithotripsy Devices
- Anesthesiology and Respiratory Devices
- General Hospital Devices
- Physical Therapy devices
- Circulatory Support and Prosthetic Devices
- General Surgery Devices