Home > Selling Leads > Bladder Scanner BVT01
- Bladder Scanner BVT01(Jiangsu)
-
Send Inquiry |
Add to Favorites |
Print
Product Name: Bladder Scanner BVT01 Product Categories: Medical devices/Diagnostic Devices Post Date: Jun 01,2016 Expiry Date: Jun 01,2017 Description: Payment Method: T/T
NEUTRAL PACKING: dongjiu
1. Brief introduction
BVT01 Bladder Volume Scanner consists of mainframe and probe.
It is a device to test bladder volume invasively with the
principle of ultrasonic scanning. It is used to evaluate
uroschesis and uroclepsia. At the same time, it offers the
opportunity objectively to conduct clinical catheterization to
reduce catheterization frequency and the risk of urinary tract
infection. By testing residual urine after urination, it can
evaluate the treatment effect to diseases of urinary system of
some medicine and therapeutic method.
2. Main technical parameters
Probe operating main frequency: 2.5 MHz
Volume calculation reference flat: 12 flats, interval 15°
Volume rendering definition: 1ml
Volume measurement range : 20ml-999ml
Volume measurement accuracy: 20ml-99ml, error less than 15ml,
100ml-999ml, error less than 15%
3.Selling points of product
3.1 Fashionable appearance design
Triangle shape conforms to principle of mechanics.
Machine casing designed with light blue and white, color of
users interface is under elaborate selection.
3.2 Humanization design
Internally installed thermal printer, safe and convenient
I-Station Industrial Station, complete data and waveform
storage, report generation and print function.
FPGA/software can upgrade online, users get updated technology
easily
Multi-language operating system, support English, Chinese,
French, Russian, Spanish, and Portuguese, meet different
countries requirements.
100 pictures can be stored in it.
3.3 Advanced function of calculate
Advanced software make sure the accuracy of scan abnormal
shapes
12 pictures prompt scanning speed, make users clear at a glance
Only one key can make image optimize, improve accuracy of
detection
Display the latest twice detection results and compare them to
confirm the detection result
Increase function of scan at any time, location more
convenient. Function of real time scan could locate the
transverse section of body before, keeping probe steady when
pick up the maximum bladder section image and start 3D scanning
can get the appropriate 3D scanning data.
3.4 Unique double power supply method
There are two kinds of power charging methods.
A.Battery charging
B.Main machine power charging
3.5 Convenient touchable screen operation
The Res Pen allocated can put in information of users and
patients on 5.7 touchable screen more easily.
Touchable screen can operated with finger which make machine
operation more humanized.
4. Standard configuration
1. Mainframe 1
2. 2.5MHz 3D probe 1
3. Power adapter 1
4. Build-in battery 1
5. charger 1
6. Touch pen 1
Optional configuration
1. Battery 1
2. Foot operated switch 1
5.Working Principal
Kaixin Bladder Volume Scanner BVT01 adopts advanced ultrasound
technology to scan patients bladder volume, which is safe and
comfortable.
6. Product Advantages
To avoid unnecessary catheterization.
To show necessary catheterization.
To reduce rate of urinary tract infection.
To avoid diagnostic undetermined uroschesis in hospital.
To help nursing staff take care of incontinence patients.
Non-invasive product.
Easy to use.
Save time for nursing staff.
Economical expenditure.
To improve patients’ nursing quality.
To improve nursing staff’s satisfaction of their work.
To avoid unnecessary hurt of patients.
7. Clinical application
Kaixin Bladder Volume Scanner BVT01 can help nursing staff
diagnose, manage and treat bladder dysfunction of patients,
includin.
A. Urinary incontinence
B. Uroschesis
C. Urinary tract infection
8.Diagnostic function
To detect residual urine volume
To distinguish disease of urinary
To diagnose potential uroschesis
To recognize blocking of catheter
To confirm drain bladder
To determine hydration status
To differentiate diverse types of uracratia to select
appropriate therapeutic schedule
9. Control and therapeutic effect
Ensure the bladder volume on the basis of intermittent urethral
catheterization scheme
(relative to time)
No need to use catheter continuously
Estimate necessary urethral catheterization after wiping off
catheter
Urination test
Estimate necessary urethral catheterization during intermittent
urethral catheterization
Make urination timetable
Bladder retraining(feedback)
10. Prophylactic function
Eliminate unnecessary catheterization
Reduce urinary tract infection proportion in hospital
Minimize the use of antibiotics for urinary tract infection
Minimize the damage to upper urethra
Prevent undiagnosed uroschesis(chronic)
Prevent postoperative uroschesis
Prevent bladder overfilling
Reduce number of uroclepsia
11. Application in urinary system
Severe outlet obstruction, lower urinery-tract syndrom,
prostatic cancer, overactivity, prostatitis diagnose.
Monitoring of postoperative recovery
Measurement of residual urine
Assessment of uroschesis
12. Meaning of using Bladder Volume Scanner
Long-term open urethral catheterization is extremely dangerous
- the intermittent catheterization can cause irreversible
damage to the bladder nerve reflex.
When patients unconsciousness, the autonomous urination
function is lost retaining catheter in patient’s body is a
clinical measure that always be taken, but long-term open
urethral catheterization is seriously dangerous.
Retaining catheter can cause damage to the bladder nerve
system, especially to the bladder nerve reflex function, and
open long-term urethral catheterization makes difficulties in
recovery of bladder autonomous urination for patients.
From the beginning that should insist intermittent
catheterization, namely closed catheter, and use Bladder Volume
Scanner monitoring bladder capacity, when bladder capacity
reaches 350-400 ml, then open the catheter urination. That
always keeping the bladder filling and emptying will confirm
bladder nerve reflex function sound.
Detaining urethral catheter would increase the dangers of
neurological bladder, use Bladder Volume Scanner can judge
patients autonomous urination function recovery timely, removal
of retaining urethral catheterization is important for
comprehensive recovery of patients and functional protection.
Retention catheter increases the chances of urinary tract
infections, and is likely to endanger the safety of the urinary
tract, using Bladder Volume Scanner can judge autonomous
urination function’s recovery, and remove indwelling urine
timely.
Bladder Volume Scanner can identify obstruction caused by the
use of catheter ,and verify the bladder capacity to prevent
bladder filling too much. Establish the bladder emptying
schedule, and make sure draft of urethral catheter removal.
13.Application to bladder management of paralyzed patients
Bladder management of paraplegia patients is an important part
of the daily care.
The main problem of taking the urethral catheter continuous
open is that patients with their own
urethral catheterization time is determined by the degree of
patients’ bladder area uplift and the experience of the
nursing staff.
Therefore, bladder excessively filling or frequent urethral
catheterization frequently occur, which is because patients or
nursing staff can not judge bladder capacity by their
experience.
That the importance of detecting bladder capacity with Bladder
Volume Scanner is, before the bladder capacity reaching the
safety capacity (Before bladder inner pressure more than
40cm/H2O, or appearing ureteral reflux to urethral
catheterization) to operate urethral catheterization. When
patients bladder overfilling happens frequently, there is
potential risk of urinary tract injury, and frequent urethral
catheterization increase the incidence of iatrogenic urinary
tract infections. While which would increase the patient's pain
and psychological burden, even easier to cause urinary tract
injury.
Each paraplegia patient without autonomous urination function
should carried by a bladder volume scanner, to continuously
monitor bladder capacity at the time of indwelling catheter,
and conduct micturition according to bladder capacity showed by
the instrument. Because long-term pen urethral catheterization
can lead to reduction of bladder capacity, frequent infections
and complete loss of bladder function. Bladder overfilling can
cause serious damage to t upper urinary tract, like
hydronephrosis etc.
Company: Xuzhou Dongjiu Electronic Technology Co., Ltd [ Jiangsu ] Address: C-01, Xuzhou Economic & Technology Development Zone, Xuzhou Contact: Richard Lee Tel: +86-516-87986760 Mobile: +86-15252079758 Fax: +86-516-87986760 Email: Freeshador@yahoo.com Disclaimer statement:The information and data included above have been realized by the enterprises and compiled by Department staff, and are subject to change without notice to you. The ChinameDevice.com makes no warranties or representations whatsoever regarding the facticity, accuracy and validity of such information and data. Our suggestion: In order to ensure your interest, we suggest registering as our gold suppliers.
- See more selling leads from this Gold Supplier:
- Browse By Category
-
- Plastic & Reconstructive Surgery Devices
- Peripheral Vascular Devices
- Interventional Cardiology Devices
- Urology and Lithotripsy Devices
- Radiological Devices
- Other Devices
- Obstetrics & Gynecology Devices
- Diagnostic Devices
- Restorative Devices
- Intraocular, Cornea and Neuromaterials Implants
- Circulatory Support and Prosthetic Devices
- Cardiac Electrophysiology & Monitoring Devices
- General Hospital Devices
- Gastroenterology and Renal Devices
- Infection Control Devices
- Physical Therapy devices
- Anesthesiology and Respiratory Devices
- Ear, Nose and Throat Devices
- General Surgery Devices
- Pacing, Defibrillator and leads
- Dental Devices
- Neurodiagnostic and Neurotherapeutic Devices
- Orthopedic Devices