630 mA x-ray equipment

informarsi

Classificazione: Others
Proprietà: Product Details:
Place of Origin:Guangdong, China
Brand Name:Ysenmed
Model Number:YSX0605
Payment & Shipping Terms:Minimum Order Quantity:1 Set/Sets
Price:FOB Guangzhou USD 0~10000
Packaging Details:double standard export packing
Delivery Time:30 days after payment
Payment Terms:L/C,T/T
Supply Ability:1 Set/Sets perMonth
Descrizione del prodotto:

Features for 630mA x-ray equipment:

1  Microcomputer control x-ray radiography assembles: optional 600mA.

2  Total 432 storage combination controlled by element such as kV mA S is applied radiography for the following filed three body position, fat middle and thin body type, automatic detect and display cod of mistake in system, send warning signal, detect accuracy and maintain.

3  X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protecionare provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.

4  Bulb type over remote-controlled diagnostic table and image intensifier television system are installed. They realize not only bright operation, but also supply convenience for science resonator suffer are reduced. Specifications of automatic spot-film are abundant. There are also automatic collimators for users convenience.

5   Applied in all kinds of hospital for radiography such as general bodybeam filtrationand chest.

Department

Technology parameters

High voltage generator control table and high voltage transform assemble

Fluoroscopy

Tube currency

0.3-5mA continuous currency

Tube voltage

50-110KV continuous voltage

Radiography

Tube currency

32-600mA shift

Tube voltage

45-125KV continuous voltage

Exposure time

0.01-6.3s 23 shift

Power

Voltage

380V±10%

Frequency

50Hz±1Hz

Capacity

≥50KVA

Inner resistance

≤0.3Ω

X-ray assembly

Focus

1×1.2×2 double focal

Rated rotate speed of anode

2800r/min

Changed beam limited device

Diagnosis table YS09D

Automatic, adjusted field of view

CS15

Electro-motion diagnostic table

The table body rotation

-15°0°+90°

Focus to film distance

11001500mm,adjustable manual

360°foot board

The table to height

870mm

Stationary grid

Grid density

40L/cm

Grid ration

101

Focusing distance

120cm

Spot film device

Scope  of moving

Longitudinal moving900mm

Transverse moving±120mm

Specification of scope film

Full :8"×10",10"×12",11"×14",14"×14"

Two:  8"×10",10"×12"

Three:11"×14",14"×14"

Four: 11"×14",14"×14"

CDG

Multi function radiography table

Moving table

Lengthways

±600mm

Electromagnetism locking

Across

±120mm

Mobile beam filtration grid

Grid density

28L/cm

Grid ratio

81

Focusing distance

100cm

Scope of moving

≥600mm

Radiography item

5×7,8×10,10×12,11×14,

12×15,14×14,14×17

Distance from surface to film

75mm

Height of bed

700mm

Moving pillar

±180°,per 90°orientation, moving lengthways ≥1500mm

Bulb tube

Rotate the cross arm±180,ascend $ descend 1100mm

 
Nome della società: Guangzhou Yueshen Import & Export Co.,Ltd
Regione: China/Guangdong
Contatto: Ms. Nancy Yi
Tel: 86-20-34050120
Contatto Fax: 86-20-34052048
Sito web: http://www.medicalxray.com.cn
Indirizzo: Room D2001,Filmtown Garden,No.350 Middle Xin'gang Road
Codice postale: 510310