Patient Monitor 7 Channel
분류: | Medical devices/Cardiac Electrophysiology & Monitoring Devices |
---|---|
재산: | Product Details: Place of Origin:China (Mainland) Model Number:AM10172 Brand Name:Amax Payment & Shipping Terms:Packaging Details:Q'ty per carton: 1pc/ctn Carton Size: 40cmx30cmx40cm Payment Terms:L/C,T/T Supply Ability:50000 Piece/Pieces perMonth |
제품 설명: | Patient Monitor 7 Channel Fuction & Specification Operating: Temperature 5~40 Humidity ≤80% Storage: Temperature -20~55 Humidity ≤93% Trend Observation :1~240 hours trend graphics Network: Compatible with central monitoring system Standard Configuration: ECG+RESP+NIBP+SpO2+HR(PR)+TEMP Optional: Built-in thermal printer,dual TEMP ECG Displaying graphics of 7 leads on the same screen Overload protection: Defibrillation. Anti the interference of high-frequency electrotome Lead: 5 Leads( RA,LA,RL,LL,V) Lead Selection: I; II;III; avR;avL;avF;V; Waveform:≤9 channels Gain Selection: X 0.5; X 1; X 2; X 4 Electrical Leakage: <30uA Baseline Recovery Time: <3 sec following defibrillation Protection: separates and withstands 4000V AC/50Hz defibrillation, resistent to interference of electrotonus and myoelectricity Scan Speed: 12.5mm/25mm/50mm/sec Lead Drop:auto detection Modes: DIA 0.05~75Hz MON:0.5~35Hz; OPE:1~25Hz RESP Model:RA-LL impedance Measurement/alarm range: 1~99rpm Resolution:1rpm. Accuracy:±2rpm TEMP Resolution: 0.1 Accuracy:±0.2 Channel: 2 channels Average measurement time: <10sec Alarm: Sound,light NIBP Method: automatic oscillometric Working Mode: Auto/Manual Interval of Auto Mode: 1~60min PR Range:0~300bpm Measurement Unit: mmHg/Kpa Selectable Measurement Ranges: Systolic BP, Diastolic BP and Mean BP Applicability: Adult/Pediatric/Neonatal Overload protection: Dual security protection SpO2 SpO2 probe of high intensity and durability Excellent measurement of low perfusion Anti interference of movment Measurement Range:0~100% Alarm Range: 0~100% Resolution: ±1% Accuracy: ±2% (80-100%); ±3% (60-79%) PR Range:0~300bpm HR A. Measurment Range: 0~300bpm B. Accuracy: ±1 bpm or ±2% C. Resolution: 1bpm D. ECG Calibration:1 mV (Peak Value) ST Segment offset( Diagnose Mode) A. Measurment Range:-1.0mV ~ 1.0mV B. Accuracy:±0.02mV or ±5% |
- Contact Info
- Selling Leads | Products
회사명: | Amax International Co.,Ltd |
지방: | China/Shandong |
접촉: | Mr. Robin Ge |
전화 번호: | +86-086-532-88735900,85781559,85710533 |
문의 팩스: | +86-086-532-88735955,85781560 |
웹사이트: | http://www.cnamax.cn |
주소: | No.18 HongKong Middle Road, Qingdao, Shandong,China. |
우편 번호: | 266071 |