Quartz-Flex Accelerometer QA2009
Clasificación: |
Medical devices/Cardiac Electrophysiology & Monitoring Devices |
Propiedad: |
Product Details: Place of Origin:Guangdong, China (Mainland) Model Number:QA2009 Payment & Shipping Terms:Payment Terms:T/T |
Descripción del producto: |
Quartz-Flex Accelerometer QA2009 Features: Highest performance accelerometer available Excellent turn-on repeatability and stability performance Analog output Three fastener precision mounting flange Field-adjustable range Dual built-in self test Internal temperature sensor for thermal compensation Description: Kogean produces the QA2009 for the highest inertial navigation-grade performance available in today's market. With high inherent quality, reliability, and long-term performance QA2009 Accelerometer, QA2009 can be applied in many applications including spacecraft navigation and control systems QA2009 provides an acceleration-proportional output current providing both static and dynamic acceleration measurement. Through the use of a customer supplied output load resistor, appropriately scaled for the acceleration range of the application, the output current can be converted into a voltage. The QA2009 includes a current-output, internal temperature sensor. Through the use of a temperature-compensating algorithm; bias, scale factor, and axis misalignment performance is dramatically improved.
The parameters below are standard. All the Quartz-Flex Accelerometers provided by Joint Sensor are customized. The price also depends on your demand.Specifications for Model: QA2009 Threshold Value/Resolution | μg | ≤|±10| | Measuring Range | g | ≥|±30| | Bias(K0) | mg | |±7| | Scale Factor(K1) | mA/g | 1.20±0.15 | Second Order nonlinear coefficient (K2) | μg/g2 | |±50| | Bias Stability (One Month) (σK0) | μg | ≤50 | Scale Factor Stability (One Month) (σK1/ K1) | ppm | ≤60 | Second Order Nonlinear Coefficient Stability (One Month)(σK2) | μg/g2 | ≤30 | Bias Temperature Coefficient(αK0) | μg/ | ≤|±60| | Scale Factor Temperature Coefficient (αK1/ K1) | ppm/ | ≤|±80| | Misalignment(δpδo) | | ≤|±120| | Noise | μA | ≤10 | Vibration | grms | [(20-2000)Hz] 5 | Shock | | 100g,5ms, 1/2sin | Low Air Pressure | | 133Pa,10min | Operating Temperature Range | | -45~+80 | Operating Voltage(DC) | V | ±15 | Dimension | mm | Φ25.4×31 | Weight | grm | ≤80 |
|
Nombre de compañía: |
Joint Sensor Instruments(Shenzhen)Ltd |
Región: |
China/Guangdong |
Contacto: |
Mr. Xingkai Chen |
Tel: |
86-755-83104666 |
Fax de contacto: |
86-755-83116697 |
Sitio web: |
http://www.sensorspower.com,www.kogean.net,www.kogeansensor.com |
Dirección: |
B401, No. 8 Lane 1 Anhua Industrial Park, Section 35 Baoan District |
Código postal: |
518000 |