Maternal&Fetal Monitor CMS800F

enquêter

Classification: Medical devices/Diagnostic Devices
Description du produit: Maternal&Fetal Monitor CMS800F Features Single or Twins Ultrasound transducer Data Graph and Trend Table Review of both mother and fetal Built-in thermal printer Programmable alarms Built-in Network capability for connect with central monitoring software All the colors and looks or the parameters can be customized Multi-face views, select focus on mother or fetal Storage of patient information and data Performance Specifications Display: 8.4" Color TFT Resolution: 640x480 Display Mode: Standard View, Fetal View, Mother View Indicator: Power indicator light, Alarm sound Interface: Socket for connecting fetal's FHR, TOCO, and Fetal Movement Sensor Socket for connecting mother's ECG, NIBP and SpO2 sensor. Net Socket(RJ45) for communication cable with Central Monitoring Station Software. Power Supply: AC 100 ~ 240V, 50/60Hz, Power < 60VA Trend Graph: Resolution from 1s, 5s, 10s. Maximum time 96 hours. Trend Table: Resolution from 1s, 5s, 10s. Review up to 1000 items. Alarm: Adjustable High and Low limits. Three level audible and visual alarm. User Configuration: All the color of parameters and waves can be set according to user's willing. Technical specifications Meet the requirement of IEC60601 series Degree of Protection: BF Type of Protection: Class II with internal electric power supply Dimention: 92(W)x82(H)x22(D)mm Weight: 136g(with battery) FHR Ultrasound Frequency: 2MHz Range: 50 ~ 210 bpm Resolution: 1BMP Accuracy: ± 2BMP FETAL MOVEMENT Manual fetal movement mark SpO2 Measurement Range: 0 ~ 100% Resolution: 1% Accuracy: ± 2%(70%~100%, Adult/Pediatric, non-motion) ± 3%(70%~100%, Neonate, non-motion) 0% ~ 69% unspecified Alarm Range: 0% ~ 100% Refreshing Rate: 1s Pulse Rate Measurement Range: 25 ~ 250 bpm Resolution: 1bpm Accuracy: ± 3 bpm (non-motion) ECG Lead mode: 3-lead or 5-lead Lead selection: I, II, III, AVR, AVL, AVF, V HR range: 15 ~ 300 bpm ECG Waveform: 2 channals Accuracy: ± 2bpm or ± 2%, which is greater S-T segment detection range: -2.0mv ~ +2.0mv Arrhythmia analysis: 13 kinds of arrhythmia Alarm Range: 15 ~ 300 bpm Alarm Range: 25 ~ 250 BMP Refreshing Rate: 1s NIBP Method: Oscillometry Mode: Manual/Auto/Contiuous Measurement Range: 25 ~ 260mmHg Auto Measure Interval: 5, 10, 15, 30, 45, 60, 90 minutes Resolution: 1mmHg Overpressure Protection: 300mmHg Alarm range: 25 ~260mmHg
Nom de l'entreprise: Perlong Medical Equipment Co.,Ltd
Région: China/Jiangsu
Contact: Ms. Helena
Tel: 86-25-52635350
Fax: 86-25-52635356
Site Web:
Adresse: Room 2807, No. 120 Hanzhong Road, Nanjing, Jiangsu, China
Code postal: