Translate :  China

Popular Searches : cotton ball , disposable infusion , Blood Collection Tub , Oxygen concentrator , disposable syringes , Autoclave , Tourniquet more>>
Home > Products > Portable Patient Monitor
 KR

Portable Patient Monitor

  • Product Detials:

    Portable Patient Monitor

    Specifications:

    Safety: IEC60601 approval (GB9706)

    Dimension: 390mm(W)×360mm(H)×117mm(D)

    Power Supply: 100-240V AC50Hz/60Hz

    Alarm Indication: Visual and audible alarm

    1000 groups of alarm events review

    Application: Adult, pediatric and neonate

    ECG

    Leads: I, II, III, aVR, aVL, aVF, V1-V6

    Gains: 5mm/mV, 10mm/mV, 20mm/mV, auto

    Input impedance: ≥5MΩ

    Common Mode Rejection Ratio: ≥100dB

    Bandwith: 0.5-25Hz(monitoring mode)

                   0.05-75Hz(diagnostic mode)

                   1-15Hz(surgical mode)

    Protection: Segregation breakdown voltage:4000VAC, 50/60Hz

    Resistant to high-frequency electro tome, myoelectricity, AC, drifting interference

    Indication of cardiogram: Available

    Scanning Speed: 25mm/s, 50mm/s

    Heart Rate Range: 20-254bmp

    Accuracy: ±1bmp

    ECG waveform play back: 20 minutes

    NIBP

    Method: Automatic oscillometrin

    Operation Modes: Single (manual), cycle (automatic), rapid (continuous)

    Measurement: Systolic/diastolic/mean

    Range: Adult: 0-300mmHg

    Pediatric: 0-210mmHg

    Neonate: 0-145mmHg

    Unit: mmHg/kPa selectable

    Auto Measurement: 1, 2, 3, 4, 5, 10, 15, 20, 30, 45, 60, 90 minutes. 2, 4, 8 hours

    750 groups of NIBP measuring data review

    RESP

    Method: Impedance Measurement

    Measuring Range: 0-170 times/min

    Alarm: 0-170bpm, upper and lower limit continuously adjustable

    SPO2

    Range: 0-100%

    Accuracy: ±2% (70-100%), ±3% (40-69%)

    Range of pules rate: 20-250BPM±1BPM

    TEME

    Channel: 2 channels

    Range: 0-50

    Unit: Celsius, Fahrenheit

    Resolution: 1mmHg

    Accuracy: ±0.1

    Alarm Range: 0-50

    IBP

    Channel: 2 channels

    Range: 0-300mmHg

    Accuracy: ±0.1

    Resolution: 1mmHg

    Accuracy: ±5mmHg (±5%)

    Unit: mmHg, kPa

    Conver Sensitivity: 5µ V/V/mmHg

    Transducer sites: ART, PA, CVP, LAP, RAP, ICP

    Standard configuration

    ECG, HR, RESP, NIBP, SPO2, PR, TEMP, Battery

    Option

    12 lead ECG, 2-TEMP, 2-IBP, Recorder, Nellcor SPO2

Inquiry About Portable Patient Monitor* is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: Triup International Corp.
Area: China/Jiangsu
Contact: Ms. Amy Lei
Tel: 86-25-52334966
Fax: 86-25-52334076
Web site: www.triup.com
Add: Room 1103, Building 2, 321 Zhongshan South Road, Nanjing, Jiangsu, China
Zip: 210001

Supplier's information
   Triup International Corp.

     Established in 2002, as one of Chinese professional medical equipment supplier, we specialize i ..... more >>

Contact: Ms. Amy Lei 

(I want to be a Gold Supplier>>)

Other products from this supplier

>>More

View the similar products

>>Search More