x-ray unit
- Product Name:
x-ray unit
- Category: Medical devices/Cardiac Electrophysiology & Monitoring Devices
- Package: woodend case
- Price: Get Latest Price
- Product Detials:
MAIN CHARACTERISTICS
1. Single bed and single bulb.
2. Design according to the electric mechanism of middle-size machine. The function is full and reasonable.
3. The high-tension system is of march-past structure. Equipped with afullwave rectification high-voltage generator and independent X-ray tube unit, with large output power and reliable and stable operation.
4. Supply voltage V,roentgenoscopy,photograpy KV and steeples adjustable.
5. Equipped with the manostat for filament of X-ray tube and the space charge compensator as to ensure the stable and accurate output.
6. Equipped with the capacity limitation and protection circuit and KvmA sinterlock limitation and protection.
7.Adopt the digital circuit timer,grade according to R10 prioritycoefficient and can control time exactly
8. Examining bed is of electirc back rotation and is equipped with vibrating filter-ray device.
9. The spot film device of luminescent screen can hold the film jacket of various sizes and can solenoid valve locking.
10. The upright post is of top and bottom track.It moves lightly.
TECHNICAL PARAMETER
ITEM
CONTENT
INDEX
Roentgenoscopy
voltage50~95KV
50~95KV Be adjustable continuously
current
0.5~5mA
Photography
voltage50~100KV 50~125KV Be adjustable continuously
current
small focus 50mA and big focus 50 100 150 200mA five grades together
spot film
150mA(fixed)
time
0.04~6.3s,23 grades together
High-Voltage generator
capacity
20KVA(instantaneous)
Max. Dc output voltage100KV 125KV
Max. Dc output current200mA
X-Ray tube
model
XD51-20.40/100 XD51-20.40/125
focus
1X1mm 2X2mm
Examining
rotary angle
+90 o ~ 0 o ~ -10 o
specifi-cation of spot film(stomach and intestines photograpy)
lengthwise 500mm
transverse ±80mm
pressure down 300mm
TECHNICAL PARAMETER
Examining bed
specifi-cation of spot film
127X177.8mm(5X7)
203.2X254mm(8X10)
254X304.8mm(10X12)
279.4X355.6mm(11X14)
filter-ray device
grid characteristic
N28
Convergence distance
fo 100cm
Grid ratio
r8
distance between bed face and film
75mm
overrunning governor
manual single blade
Upright post
adjusting scope (distance between top and bottom track)
2800-3400mm
move lengthwise
(along top and bottom track)
3100mm
move transverse
(along horizontal arm)
800mm(from bulb focus to the centre of upright post)
move up and down
(along upright post)
930~1830mm(from bulb focus to the centre of upright post)
Supply power
voltage380V/220V
frequency
50Hz ± 0.5Hz
inner resistance
380V:0.9 Ω ,220V:0.3 Ω
- Inquiry About x-ray unit* is required.
- Contact Info
-
Company: China Yangzhou Guo Tai Co.,Ltd Area: China/Jiangsu Contact: Mr. Dajing Sun Tel: 86-514-87852272 Fax: 86-514-85100806 Web site: Add: 3/f, 18 Wenchang West Road, Yangzhou, Jiangsu, China(mainland) Zip: 225012
- Supplier's information
-
China Yangzhou Guo Tai Co.,Ltd
Established in 2001, China Yangzhou Guo Tai Co., Ltd. is a foreign trading company sanctioned b ..... more >>
- View the similar products
-
Oh,it has no brothers!