Patient Monitor (SW-I)

- Product Name:
Patient Monitor (SW-I)
- Category: Medical devices/Diagnostic Devices
- Price: Get Latest Price
- Product Detials:MODEL NUMBER: SW-I Specification: 1. General Specifications: Size:154mm×128mm×40mm Net Weight: 480g Display Specification Measurement Display: color LCD/touch screen Power Supply Indicator: Dual-color LED (red/green) Beat indicator: Dual-color LED (red/green) 2. Power Supply AC Power Adaptor Input: 100~240VAC, 50/60Hz, 0.7A Output: DC 4.2V, 800mA Battery Li-ion rechargeable battery, 3.7V, 5AHr Operating Time: 5 hours with full battery capacity. , NIBP working period is 10 minutes) Recharge Time: 10 hours. 3. Environment Temperature Working:0 ~ 45 (°C) Transport and Storage: -25~ 85 (°C) Humidity Working:30% ~85 % Transport and Storage: 30% ~95 % (no condensation) 4. Monitoring Parameter ECG: Input:3- lead ECG cable, standard AAMI cable connector Lead Selection:I,II,III Gain Selection:×1,×2,×4,×8 Sweep Speed: 12.5, 25, and 50 mm/s Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB) Calibration Signal: 1mV square wave Protection: Against electrosurgical interference and defibrillation Heart Rate: Measuring Range: 30~250 bpm Renew Time: 1 time per beat Accuracy: ±1 bpm Alarm Mode: Audible and visual alarm SpO2: SpO2% Measuring Range:0~100% Resolution:1 % Accuracy:±2 %(70%~99%), unspecified (0%~69%) Pulse Rate: Measuring and Alarm Range:0~250bpm Resolution: 1bpm Accuracy: ±1bpm NIBP: Method: Oscillometric Mode: Manual, Auto, STAT Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 60 (min) Measuring Period in STAT Mode: 5 min Cuff Pressure Range:0~300 (mmHg) Pulse Rate Range:30~250 (bpm) Measurement Rage: Adult 30~255mmHg, Pediatric 30~160mmHg Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg Pressure Resolution : 1mmHg The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using blood pressure measurement device. Temperature: Input: Body surface thermal-sensitive resistor temperature sensor Measuring Range: 0~50oC Accuracy: ±0.1oC 5. Storage and Review Maximum Data Quantity: 3888 groups Maximum Trend Time: Continuous 129 hours
- Inquiry About Patient Monitor (SW-I)* is required.
- Contact Info
-
Company: Ruian Sunnyworld Medical Instruments Co.,Ltd Area: China/Zhejiang Contact: Mr. Manny Chen Tel: 86-577-65917211 Fax: 86-577-65910855 Web site: http://www.sunnyworld.cn Add: 11 Bulding, Xinda Road, Ruian, Wenzhou, Zhejiang, China Zip: 325200
- Supplier's information
-
Ruian Sunnyworld Medical Instruments Co.,Ltd
Ruian Sunnyword Medical Instruments Co., Ltd. With abundant manufacturing experience, professio ..... more >>
- View the similar products
-