Fetal Monitor FMF

- Product Name:
Fetal Monitor FMF
- Category: Medical devices/Diagnostic Devices
- Price: Get Latest Price
- Product Detials:Features: Single or Twins Ultrasound transducer Data Graph and Trend Table Review of both mother and fetal Built-in thermal printer, Programmable alarms All the colors and looks or the parameters can be customsized Multi-face views, select focus on mother or fetal Storage of patient information and data Performance Specifications: Display: 8.4" Color TFT Resolution: 640x480 Display Mode: Standard View, Fetal View, Mother View Indicator: Power indicator light, Alarm sound Interface: Socket for connecting fetal's FHR, TOCO, and Fetal Movement sensorSocket for connecting mother's ECG, NIBP and SpO2 sensor. Net Socket(RJ45) for communication cable with Central Monitoring Station Sofrware. Power Supply: AC 100 ~ 240V, 50/60Hz, Powe < 60VA Trend Graph: Resolution from 1s, 5s, 10s. Maximum time 96 hours. Trend Table: Resolution from 1s, 5s, 10s. Review up to 1000 items. Alarm: Ajustable High and Low limits. Three level audible and vistual alarm. User Configuration: All the color of parameters and waves can be set according to user's willing. Technical specifications: Safety Meet the requirment of IEC60601 series Type of Protection: Class II with internal electirc power supply Degree of Protection: BF Dimention and Weight Dimention: 92(W)x82(H)x22(D)mm Weight: 136g(with battery) Operation Environment: Temperature: 0~ +40 degree Humidity: 15% ~ 95% Storage Environment: Temperature: -20~ +60 degree Humidity: 10% ~ 95% Patient Range: Pregnant Adult FHR: Ultrasound Frequency: 2MHz Range: 50 ~ 210 bpm Resolution: 1BMP Accuracy: ± 2BMP TOCO: Range: 0 ~ 100% Resolution: 1% Non-linear Error: <=± 8% Zero control: Manual FETAL MOVEMENT: Manual fetal movement mark SpO2: Measurement Range: 0 ~ 100% Resolution: 1% Accuracy: ± 2%(70%~100%, Adult/Pediatric, non-motion) ± 3%(70%~100%, Neonate, non-motion)0% ~ 69% unspecified Alarm Range: 0% ~ 100% Refreshing Rate: 1s Pulse Rate: Measurement Range: 25 ~ 250 bpm Resolution: 1bpm Accuracy: ± 3 bpm (non-motion) Alarm Range: 25 ~ 250 BMP Refreshing Rate: 1s ECG: Lead mode: 3-lead or 5-lead Lead selection: I, II, III, AVR, AVL, AVF, V HR range: 15 ~ 300 bpm ECG Waveform: 2 channals Accuracy: ± 2bpm or ± 2%, which is greater S-T segment detection range: -2.0mv ~ +2.0mv Arrhythmia analysis: 13 kinds of arrhythmia Alarm Range: 15 ~ 300 bpm NIBP: Method: Oscillometry Mode: Manual/Auto/Contiuous Measurement Range: 25 ~ 260mmHg Atuo Measure Interval: 5, 10, 15, 30, 45, 60, 90 minutes Resolution: 1mmHg Overpressure Protection: 300mmHg Alarm range: 25 ~260mmHg Built-in Network capability for connect with central monitoring software
- Inquiry About Fetal Monitor FMF* is required.
- Contact Info
-
Company: Sunshine Medical Equipment Co.,Limited Area: China/Jiangsu Contact: Ms. Eva Tel: 86-25-52157547 Fax: 86-25-52157547 Web site: http://www.sunshinemedical.net Add: No. 91 Baixia Rd., Nanjing, Jiangsu, China Zip: 210029
- Supplier's information
-
Sunshine Medical Equipment Co.,Limited
Sunshine Medical Equipment Co., Limited We are professional medical equipments and Bea ..... more >>
- Other products from this supplier
-
-
Fetal Monitor FMF
-
Automatic Vertical Pressure Steam Autoclave N Class 50L
-
HF First-Aid Ventilator
-
Fingertip Oximeter FOD
-
Operating Table (JT-2B)
-
Kelman-Mcpherson Toothed Forceps
-
Deflective Pillar Operating Table (JT-3)
-
Multipurpose Gynecological Table (FC-1)
-
Male Sexual Dysfunction Diagnostic and Therapeutic Machine (501-4)
-
Tractor for Orthopedics (QY-1)
-
- View the similar products
-