Muti-Parameter Patient Monitor (CLD9000)

- Product Name:
Muti-Parameter Patient Monitor (CLD9000)
- Category: Medical devices/Diagnostic Devices
- Price: Get Latest Price
- Product Detials:Features Color TFT Screen, waveform up to 8 channels Light and portable with build-in rechargeable battery UP to 10 kinds of monitor parameters Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis 72 hour storage and review of trend grams and tables, 40 second review of olographic wavefo rms. Built-in recorder(option) All-round monitor of adult, pediatric and neonatal. Electrosurgical unit and defibrillation protected Standard parameters: ECG, NIBP, SPO2, Respiration, Temperature, Pulse rate Option parameters: EtCO2, CO, IBP, Thermal Printer ECG 5-lead or 3-lead selectable Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C Lead selection: I; II; III; AvR; AvL; AvF; Vx; CAL Gain selection: 12.5mm/s, 25mm/s, 50mm/s Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation Operation modes: Diagnostic, Monitor, Surgery Alarm range: Adult: 15-300bpm Pediatric/Neonatal: 15-350bpm Alarm range: -2.0mV~2.0mV S-T detection: YES, Arrhythmia analysis: YES Alarm: YES, audible and visual alarm, alarm events recallable NIBP Method: Oscillometry Operation modes: Manual/Automatic/STAT Measurement unit: MmHg/KPa selectable Measurement types: Systolic, Diastolic, Mean Measurement range: Adult: 10-270mmHg Over-pressure protection: YES Resolution: 1mmHg Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10 Alarm: Systolic, Diastolic, Mean SpO2 Measurement range: 0-100% Accuracy:? Digit (70~100%); 0~69% unspecified Alarm range: 0-100% Respiration Method: RA-LL impedance Pediatric/Neonatal: 6-150rpm Alarm range: Adult: 6-120rpm Pediatric/Neonatal: 6-150rpm Apnea alarm: YES Temperature Resolution: 0.1C Channel: Dual-channel Alarm range: 0-50C Option: EtCO2 Measurement Mode: Side-stream or mainstream Measurement range: EtCO2: 0-99mmHg Accuracy: CO2 concentration Apnea alarm: YES CO Method: Thermo-dilution Measurement range: CO: 0.1-20 lit. /min. NIBP Channel: 2 channels Pressure transducer: Sensitivity: 5( mV/V/mmHg) Transducer sites: ART, PA, CVP, RAP, LAP, ICP Alarm range: -10~300mmHg More Product Features Model NO.: CLD9000 Standard: CE, ISO Min. Order: 1 Company: RuiAn Careland Medical Co., Ltd.
- Inquiry About Muti-Parameter Patient Monitor (CLD9000)* is required.
- Contact Info
-
Company: RuiAn Careland Medical Co.,Ltd Area: China/Zhejiang Contact: Mr. Sam Lee Tel: Fax: Web site: Add: Ruian Economic Development Zone, Wenzhou, Zhejiang, China Zip: 325200
- Supplier's information
-
RuiAn Careland Medical Co.,Ltd
Careland medical Co., Ltd. is focusing on research, manufacture and distributioon of medical in ..... more >>
- Other products from this supplier
-
-
Ambulatory Blood Pressure Monitor (CLD-06)
-
Ultrasound Scanner (600C/600D)
-
TLC Series Dynamic ECG ( DCG) System (TLC9804, TL2000, TLC4000)
-
Ultrasound Scanner (280A)
-
Pulse Oximeter (CLD-50B)
-
Portable Convex (600A)
-
Fetal Monitor (CLD-800G)
-
Muti-Parameter Patient Monitor (CLD9000)
-
Twelve Channel (ECG-9012)
-
Pulse Oximeter (CLD-50C)
-
- View the similar products
-