Digital X-ray Radiography System

- Product Name:
Digital X-ray Radiography System
- Category: Laboratory Equipment
- Package: original exporting package
- Price: Get Latest Price
- Scope:body test
- Product Detials:SpecificationsDigital photography X-Ray system
Applied to the chest, skull, spine and limbs of the X-ray digital imagePartsa) High frequency and high voltage generator;b) X-Ray original parts;c) Beam limit device;d) High-voltage cable;e) Photographing bed;f) Motor-driven suspension photographing shelf;g) CCD image detector;h) Image-processing system;i) Grid;j) High voltage cablek) Automatic exposure control ionization chamber(optional)1.8 Work Conditions1.8.1 Environment Conditiona) Environment temperature(10~35)°C;b) Comparative humidity≤35%~75%;c) Atmospheric pressure(70~106)KPA .1.8.2 Power Conditiona) The power voltage of high frequency and high voltage generator is three-phase380V, 50Hz. The permitted change scope of power voltage is 380V±38V, the permitted change scope of the frequency value is 50Hz±1Hz.The power of photographing is with single-phase , 220V±22V, 50Hz±1Hz;b) Power internal resistance: AC380V power, should be no more than 0.17Ω;c) Input power: 32 kVA;d) Power capacity: ≥35 kVA.1.9 Technique Target and Parameter1.9.1 Powera) Maximal output power: 20kW(100kV, 200mA);b) Nominal electric power: 20kW(100kV, 200mA, 0.1s).When the maximal kilovolt (KV) is 150KV, the maximal milliampere is 125mA; when the maximal milliamphere is 200mA, the maximal kilovolt (KV) is 100KV.1.9.2 X-Ray Tube Voltagea) Take type E7843X, type RAD-14 X-Ray tube voltage adjustment as step-type recording, adjustment scope is(40~150)kV, each grade 1kV;b) Take type E7242X X-Ray tube voltage adjustment as step-type recording, adjustment scope is 40~125)kV, each grade 1kV;c) The deviation of X-Ray tube voltage value should be no more than 10%.Storage and Transportationa) Environment temperature 15º~35º;b) Comparative humidity 45%~75%;c) Atmosphere pressure 86 KPA~106 KPA;d) Storage and transportation requests of detector: environment temperature scope: -20ºC~55ºC;comparative humidity scope:≤93%;atmosphere pressure scope:50KPA~106KPA.
- Inquiry About Digital X-ray Radiography System* is required.
- Contact Info
-
Company: Beijing Dotop S&T Co.,Ltd. Area: China Contact: Sheila Tel: 010-60551766 Fax: 010-60551528 Web site: www.dotopmed.com Add: A-703 Room Jiaye Building No.5 the third North Rind Road Fengtai Zone Zip: 101101
- Supplier's information
-
Beijing Dotop S&T Co.,Ltd.
Dotop medical equipment group was found in 2000. It is a high-tech enterprise engaged in sc ..... more >>
- Other products from this supplier
-
-
Lab Instrument Urine Analyzer
-
Clinitek50/100/500 urine test strips
-
Urine test strips B11-B
-
Multi-parameters Urine Test Strips
-
Laboratory Equipment
-
BT-200 Matched Uirne Test Strips
-
Clinical Medical Equipment DT-380
-
Auto Chemistry Analyzer DT-480
-
Full Auto Urine Analyzer
-
Sell High Speed Urine Test Machine BT-600
-