Atomic Absorption Spectrophotometer (WFX-110B)

  • Product Detials:

    Atomic Absorption Spectrophotometer (WFX-110B)

    The patented flame analysis technique adopting oxygen-rich air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses.
    Automatic hollow cathode lamp changeover. The high performance HCL can be used directly.
    Auto-changeover and position optimization of integrated flame.
    Auto-ignition, automatic spectral bandwidth selection. Fully automated wavelength scanning and peaking
    Perfect safety protection measures, alarm and automatic safety protection to fuel gas leakage, air pressure deficiency and abnormal flame extinction; spray chamber made of explosion-proof material, all-titanium burner and explosion-proof stopper for flame analyses; alarm and protection function to argon pressure deficiency, insufficient cooling water supply, over-heating and over-current etc. in graphite furnace analyses.
    Adopting large-scale programmable logic array and Inter IC bus technique and highly reliable adapters for electric design.
    Easy and flexible WINDOWS operating system, with multi-windows processing technology to observe the signal profile, the measured results and the calibration curve at the same time. Various analytical programs, data, signals and graphics can all be stored for later use.

    Main Specification

    Wavelength range

    190-900nm

    Wavelength accuracy

    ±0.25nm

    Resolution

    Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.

    Baseline stability

    ≤0.004A/30min

    Background correction

    The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times.

    Hollow Cathode Lamps

    Lamp turret

    6-lamp turret, fully automated scan and peak-picking.

    Lamp current adjustment

    Automatic adjustment and display. Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA 

    Lamp power supply mode

    Powered by two pulses simultaneously 

    Optical System

    Monochomator

    Single beam, Czerny-Turner design grating monochromator

    Grating

    1800 l/mm

    Focal length

    277mm

    Blazed Wavelength

    250nm

    Spectral Bandwidth

    0.1nm, 0.2nm, 0.4nm, 1.2nm automatic change.

    Atomizer

    Flame/Graphite

    Flame & Graphite Furnace atomizer automatic changeover

    Detection and Data Processing System

    Detector

    Photomultiplier with high sensitivity and wide spectral range.

    Software

    Ms-Windows 98/Me operating system

    Analytical method

    Working Curve Method (1st order and 2nd order fitting), Sensitivity auto-correction, Standard Addition Method.

    Concentration

    Auto-calculation of concentration and content

    Repeatable measurement

    Maximum 20 times of repeat measurement, automatic calculation of mean value, standard deviation and relative standard deviation.

    Multi-task function

    Sequential measurement of multi-elements in one sample

    Condition reading

    With model function

    Result printing

    Measurement data and final analytical report printout, editing with Excel.

    Flame Analysis

    Burner

    10cm single slot all-titanium burner

    Spray chamber

    All-plastic spray chamber.

    Nebulizer

    High efficiency glass nebulizer with metal sleeve.

    Position adjustment

    Adjusting mechanism for vertical, horizontal positions and the rotation angle of the burner.

    Protection for gas system

    Fuel gas leak protection, abnormal flame extinction alarm, air-pressure deficiency protection and explosion-proof device.

    Flame ignition

    Automatic

    Characteristic Concentration and Detection Limit

    Normal Air-C2H2 flame

    Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L;

    Oxygen-rich Air-C2H2 flame

    Ba: Characteristic concentration ≤ 0.22mg/L Al: Characteristic concentration ≤ 0.4mg/L

    Hydride generation

    Hg: detection limit≤0.5ug/L

    Power Supply

    220V, 200W

    Dimensions

    1020 (L) × 492 (W) × 537 (H) mm (main unit)

    420 (L) × 420 (W) × 460 (H) mm (graphite furnace)

    Weight

    Unpacked 80kg (main unit), 50kg (graphite furnace)

Inquiry About Atomic Absorption Spectrophotometer (WFX-110B)* is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: Tsingtao Unicom-Optics Instruments Co.,Ltd
Area: China/Shandong
Contact: Mr. Domty
Tel: 86-532-88480588
Fax: 86-532-88480587
Web site: www.unicomoptics.com
Add: Building 2, Huanghai West Road, Laixi City, Qingdao, Shandong, China
Zip: 266600

Supplier's information
   Tsingtao Unicom-Optics Instruments Co.,Ltd

     Tsingtao Unicom-Optics Instruments Co., Ltd. Tsingtao Unicom-Optics Instrumen ..... more >>

Contact: Mr. Domty 

(I want to be a Gold Supplier>>)

Other products from this supplier

>>More

View the similar products

>>Search More