  • Product Detials:PATIENT MONITOR 

    1.20 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titration table

    2. Efficient resistance to interference of defibrillator and electrosurgical cautery

    3. SPO2 can testing for 0.1% Weak

    4. RA-LL impedance Respiration

    5. Trend Coexist Display

    6. OxyCRG DyNamic View Display

    7. Bed to Bed view Display

    8. Networking capacity and nurse_calling system

    9. Options of printing, IBP, VGA and EtCO2.

    10. UP to 4 hours working capacity of built_in rechargeable battery.

    11, 12.1"high resolution color TFT LCD display.

    12, Large volume of tabular and graphic trends information storage and easy to recall.

    13, Anti-ESU, anti- defibrillator

    14, 6 Standard parameters:ECG,RESP,NIBP,SPO2,1_TEMP,PR/HR.

    15, Capture dynamic waveforms.

    Product Specification

    Lead Mode: 5 Leads (    R, L, F, N, C or RA, LA, LL, RL,V)

    Lead selection: I, II, III, avR, avL, avF, V,

    Waveform: 2 ch

    Lead mode: 3 Leads ( R, L, F or RA, LA, LL)

    Lead selection: I, II, III,

    Waveform: 1 ch

    Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV,  auto

    HR and Alarm       

    Range    

    Adult: 15 ~ 300 bpm

    Neo/Ped: 15 ~ 350 bpm

    Accuracy       : ± 1% or ± 1bpm,which great

    Resolution: 1 bpm

    Sensitivity: > 200 (uV P-P)

    Differential Input Impedance: > 5 MΩ

    CMRR

    Monitor: > 105 dB

    Operation: > 105 dB

    Diagnosis: > 85 dB

    Electrode offset potential: ±300mV

    Leakage Current: < 10 uA

    Baseline Recovery: < 3 S  After Defi.

    ECG Signal Range: ±8 m V ( Vp-p )    

    Bandwidth  

    Surgery: 1 ~ 15 Hz

    Monitor: 0.5 ~ 35 Hz

    Diagnostic: 0.05 ~ 100 Hz

    Calibration Signal: 1 (mV p-p),  Accuracy:±5% 

    ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV

    ARR Detecting      

    Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

    Alarm: Available

    Review: Available

    ARATION

    Method: Impedance between R-F(RA-LL)

    Differential Input Impedance: >2.5 MΩ

    Measuring Impedance Range:       0.3~5.0Ω

    Base line Impedance Range: 0 2.5  KΩ

    Bandwidth: 0.3 ~ 2.5 Hz

    Resp. Rate

    Measuring and Alarm Range 

    Adult: 0 ~ 120 rpm

    Neo/Ped: 0 ~ 150 rpm

    Resolution: 1 rpm

    Accuracy       : ±2 rpm

    Apean Alarm: 10 ~ 40 S

    Mode: Manual, Auto, STAT

    Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)

    Measuring Period in STAT Mode: 5 Min

    Pulse Rate Range: 40 ~ 240 bpm

    Alarm Type: SYS, DIA, MEAN

    Measuring and alarm range                 

      Adult Mode

    SYS: 40 ~ 270 mmHg

    DIA: 10 ~ 215 mmHg

    MEAN: 20 ~ 235 mmHg

      Pediatric Mode

    SYS: 40 ~ 200 mmHg

    DIA: 10 ~ 150 mmHg

        MEAN:20 ~ 165 mmHg

    Neonatal Mode

    SYS: 40 ~ 135 mmHg

    DIA:10 ~ 100 mmHg

    MEAN:20 ~ 110 mmHg

    Resolution Pressure:1mmHg

    Accuracy       Pressure  Maximum Mean error: ±5mmHg

    Maximum Standard deviation: ±8mmHg

    Overpressure Protection

    Adult Mode: 297±3 mmHg

    Pediatric Mode: 240±3 mmHg

    Neonatal Mode: 147±3 mmHg

    Alarm Range: 0 ~ 100 %

    Resolution: 1 %

    Accuracy       : 70% ~ 100% ±2 %

         0% ~ 69% unspecified

    Actualization interval: about 1 Sec.

    Alarm Delay: 10 Sec.

    Pulse Rate

    Measuring and Alarm Range: 20~300bpm

    Resolution: 1bpm

    Accuracy       : ±2bpm

    Channel: 1

    Measuring and Alarm Range: 0 ~ 50 °C

    Resolution: 0.1°C

    Accuracy       : ±0.1°C

    Actualization interval: about 1 Sec.

    Average Time Constant:<10 Sec.

    Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

    Measuring and alarm range

    ART: 0 ~ 300 mmHg

           PA: -6 ~ 120 mmHg

           CVP/RAP/LAP/ICP: -10 ~ 40 mmHg

           P1/P2: -10 ~ 300 mmHg                                  

    Press Sensor

    Sensitivity: 5 uV/V/mmHg

    Impedance: 300-3000Ω

    Resolution: 1 mmHg

    Accuracy       : ±2% or ±1mmHg, which great

    Actualization interval: about 1 Sec.

Inquiry About patient monitor* is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: Shenzhen Kaguwi Imp & Exp Co.,Ltd
Area: China/Guangdong
Contact: Mr. Charlie Kong(Export De
Tel: 86-755-25864513
Fax: 86-755-25864103
Web site: http://www.kaguwi.com
Add: 9c, No5, Hongling Building, Hongling South Road, Futian Dist., Shenzhen, Guangdong, China
Zip: 518031

Supplier's information
   Shenzhen Kaguwi Imp & Exp Co.,Ltd

     Shenzhen Kaguwi Imp&Exp Co., Ltd. is a leading export company who will mainly export medical an ..... more >>

Contact: Mr. Charlie Kong(Export De 

(I want to be a Gold Supplier>>)

Other products from this supplier

>>More

View the similar products

>>Search More