Fetal Monitor (L8)
Clasificación: | Medical devices/Diagnostic Devices |
---|---|
Descripción del producto: | Features
Lightweight, space-saving, easy operation Interface of parameters like FHR, TOCO, FM with digital and curve display Battery indication, pregnant No display Alarm system 7 inch TFT color screen which can be fold up to 90 degrees Build-in long life thermal printer DSP technology, realtime identify and measurement for FHR, results will be accurate and reliable. 12hours date memory that can be playback and printed Special patient event and clinical event marking bottom Low ultrasound power safe to fetal, safe to fetal Wide range of applying voltage (100-240v) Automatic Fetal Movement Detection. 2.1 Standard compages Main unit. Adapter and power wire. 3 in 1 transducer (U/S, TOCO and Remote Even market), U/S2 transducer(option), maternal SpO2 sensor(option), blood pressure cuff(option). Main unit the main unit has the LCD module, recorder and electronic circuitry-microprocessor, signal Processing, audio system, display systems and power supply. Signals from the transducers are Processed and displayed on the large LCD display. And the menu can be adjust by encoder. The key on control panel can be set up the system parameter, freeze display, adjust volume, Printer control, alarm control and so on. Transducer 3-in-1 transducer (include U/S, TOCO and Remote Event marker). The transducer are held in Place on the abdomen by elastic straps. The pregnant woman hold the marker, push the button when she feels fetal moving or uterine activity. Ordering information Accessories below are supplied or approved by Our company Accessories series NO. Gel ( 250g one bottle ) 14101 Printer paper 14110 Technical Date Fetal/maternal monitor Fetal Heart Rate: Transducer: Multi-crystals, pulsed doppler, high sensitively Strength: <5mW/cm2 Working frequency: 1.0MHz Signal processing: Special DSP system and modern recognization. Measurement range: 50~210 bpm Alarm Range: High limit: 160, 170, 180, 190 bpm Low limit: 90, 100, 110, 120 bpm Maximum audio output power: 1.5 Watt Toco: Measurement range: 0~100 units Maternal SpO2 measure: Measure scope: 70%~99%. Measure accuracy: ± 3% Pregnant HR Measure: Measure scope: 30bpm~240bpm Measure accuracy: ± 2 bpm NIBP measure: A) NIBP-SYS (6.7~32.0Kpa)(50~240mmHg) B) NIBP-DIA (3.4~26.6Kpa)(25~200mmHg) C) NIBP-MEAN(2.0~24.0ka(15~180mmHg) NIBP Accuracy: ± 1.1kPa(± 8mmHg)or ± 5% of the results, take the bigger one. Maximum Mean error: ± 5mmHg Maximum Standard deviation 8mmHg Pulse Rate Accuracy: Maximum Mean error: ± 2bpm Measure accuracy: ± 2 bpm or ± 5% of the results, take the bigger one. Measure mode: Manual Display: The LCD displays FHR, TOCO, FM, maternal parameters, time, date, volume and so on, It can store and play Back the data. Power: A. C. 100-240V, 50/60Hz or 8.4 Li-LON Power Consumption: < 20W Dimension: 295W× 240D× 73H(mm) Net weight: 1.75kg Working Environment: Temperature: 5~40 Celsius. Relative humidity: 10~80% Transducer Acoustic Output: Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure Does not exceed 1Mpa. The output beam intensity does not exceed 20mW/cm2 And the spatial-peak temporal-average intensity does not exceed 100mW/cm2 GEL: Viscous aqueous non-sensitising, hypo-allergenic and non-irritating to skin. Indefinite shelf life, Bacteriostatic (not sterile). |
- Contact Info
- Selling Leads | Products
Nombre de compañía: | Shenzhen Luckcome Technology Inc Ltd |
Región: | China/Guangdong |
Contacto: | Mr. John Cena(Sales Department |
Tel: | 86-755-26863526 |
Fax de contacto: | 86-755-26863526 |
Sitio web: | http://www.luckcome.com |
Dirección: | 3a1 Zhenxing Building, Industrial Road 3, Shekou, Shenzhen, Guangdong, China |
Código postal: | 518054 |