Gas Chromatography (GC9790II) Capillary and packed column inlets, split and splitless, cool-on-column Programmable oven, 8 ramps temperature programming, 6 temperatures, up to 400º C Wide dynamic range of popular detectors: FID, TCD, NPD, ECD and FPD Instrument control, method setup and run from keyboard entries Rugged manual injection and manual pneumatics Self-diagnosis of controls: Thermal zone, flows, and detectors Ready to use when product delivered and installed Unbeatable price and service package Guarantee timely and no-hassle service responding Dual pneumatics | Dual packed column inlets | | GC9790IIF | Dual FID Detector | | GC9790IIT | TCD Detector | | GC979IIT-2 | TCD Detector (new type) | | GC9790IIP | FPD Detector | | GC9790IIE | ECD Detector | | GC9790IIG | Dual FID Detector, dual amplified board | | GC9790IIB | Dual FID Detector, TCD Detector | | GC9790IIB-2 | Dual FID Detector, TCD Detector (new type) | | GC9790IID | FID Detector, FPD Detector | | GC9790IIK | Dual FID Detector, ECD Detector | | GC9790IIH | TCD Detector, FPD Detector | | GC9790IIL-3 | Dual FID Detector, ECD Detector, FPD Detector | | Packed column inlet, Capillary column inlet (split and splitless) | | GC9790IIJ | Dual FID Detector | | GC9790IIR | FID Detector, NPD Detector | | GC9790IIC | Dual FID Detector, dual FID amplified board | | GC9790IIA | Dual FID Detector, TCD Detector | | GC9790IIA-2 | Dual FID Detector, TCD Detector (new type) | | GC9790III | FID Detector, FPD Detector | | GC9790IIL | Dual FID Detector, ECD Detector | | GC9790IIL-2 | FID Detector, ECD Detector, FPD Detector | | GC9790IIL-4 | FID Detector, ECD Detector, NPD Detector | | GC9790IIL-5 | FID Detector, NPD Detector | | GC9790IIL-6 | FID Detector, ECD Detector, NPD Detector | | Dual Capillary column inlets (split and splitless) | | GC9790IIQ | Dual FID Detector | | GC9790IIN | Dual FID Detector, dual amplified board | Detector: FID
| Detection limit | ≤3x10 -12 g/s | | Sensitivity Mv.ml/mg[n-C16] | | | Noise | ≤3x10 -14 A | | Drift | ≤5x10 -13 A/30min | | Linear range | ≥10 6 | Detector: TCD
| Detection limit | | | Sensitivity Mv.ml/mg[n-C16] | ≥2500 | | Noise | ≤20μV | | Drift | ≤100μV/30min | | Linear range | ≥10 4 | Detector: TCD(new type)
| Detection limit | | | Sensitivity Mv.ml/mg[n-C16] | ≥8000 | | Noise | ≤20μV | | Drift | ≤100μV/30min | | Linear range | ≥10 4 | Detector: ECD
| Detection limit | ≤1x10 -13 g/ml | | Sensitivity Mv.ml/mg[n-C16] | | | Noise | ≤20μV/30min | | Drift | ≤50μV/30min | | Linear range | ≥10 4 | Detector: FPD
| Detection limit | Mt≤1.4x10 -12 g/s(P), Mt≤5x10 -11 g/s(S) methyl parathion | | Sensitivity Mv.ml/mg[n-C16] | | | Noise | ≤4x10 -10 A | | Drift | ≤4x10 -10 A/30min | | Linear range | ≥10 3 (P), ≥10 2 (S) | Detector: NPD
| Detection limit | | | Sensitivity Mv.ml/mg[n-C16] | Mt≤5x10 -13 g/s(N) Malathion, Mt≤1x10 -12 g/s(P) azobenzol | | Noise | ≤4x10 -13 A/30min | | Drift | ≤2x10 -12 A/30min | | Linear range | ≥10 3 |
|