Home > Products > URIT-8060 Automated Chemistry Analyzer
 KR

URIT-8060 Automated Chemistry Analyzer

URIT-8060 Automated Chemistry Analyzer
  • Product Detials:Specifications: Assay methods: End Point, Kinetic, Fix time etc. Principle: Photoelectric Colorimetry Light Source: Halogen lamp 12v/20w Photometry range: 0-3.0 Abs Resolution: 0.0001Abs Wavelength: 10 wavelengths optional (340nm, 405nm, 450nm, 492nm, 510nm, 546nm, 578nm, 630nm, 700nm, 800nm) Throughput: 400 tests/hour Memory capacity: Up to 1000 items Reagent tray: 60 reagent positions Sample tray: 75 sample positions Reaction tray: 120 reaction positions Sample volume: 3-50uL, with 0.1μL increment Reagent volume: 100-450μL, with 1μL increment Minimum reaction volume: 180ul Maximal reaction time: 10 mins Water Consumption: 2.5L/hour under working status Clean unit: 8-step auto-washing Calibration: Line/non-line; Multi-standards assay (Max: 6 QC values) Control: 3 level controls for each item, analyzing and printing QC analysis diagram Fuse: T7A 250V Ambient: Relative humidity: ≤ 85% Atmospheric pressure: 86-106kPa Features: High accurate optical system, transmitted by fiber 8-step auto-washing to ensure cuvettes clean and decrease cross-contamination Optimum test sequence setting program, STAT test priority 120 reaction cuvettes located in a constant temperature incubator Durable cuvettes, adopting reused cuvettes with auto-washing system Friendly operation software, multi-language available Displaying and printing reaction curve, real time diagnosis of system working status Long life filter plated with Oxide film
Inquiry About URIT-8060 Automated Chemistry Analyzer* is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: URIT Medical Electronic Co.,Ltd
Area: China/Anhui
Contact: Ms. Tracy Yeung
Tel: 86-773-2288583
Fax: 86-773-2288560
Web site: http://www.uritest.com/Html/main.asp
Add: 4 East Alley, Jiuhua Road, Guilin, Guangxi, China
Zip: 541001

Supplier's information
   URIT Medical Electronic Co.,Ltd

     URIT Medical Electronic (Group) Co., Ltd. has developed into the biggest national manufacture b ..... more >>

Contact: Ms. Tracy Yeung 

(I want to be a Gold Supplier>>)

Other products from this supplier

>>More

View the similar products

>>Search More