Translate :  China

Popular Searches : Sphygmomanometer , medical instrument , Blood Collection Tub , Sphygmomanometer , Tourniquet , sterilizer , Dental Needle more>>
Home > Products > Patient Monitor (PDJ-3000A)
 KR

Patient Monitor (PDJ-3000A)

Patient Monitor (PDJ-3000A)
  • Product Detials:Specifications: Performance: Display: 12"color TFT display to show 4~9 waveforms Resolution: 640x480 or 800x600 Interface: Interface for CRT display and net card Tend observation: Tend chart of 1 - 72 hours Alarm: Upper and lower limit alarm, audible and Visual, third grade alarm Connection: Can be connected to central monitor and Long-distance monitor Memory method: Manual, alarm, timing, etc. Optional configuration: Printer ECG: Configuration: 3 or 5 lead Lead input: 5 lead: RA, LA, RL, LL, V Lead Selection: AvR, avL, avF, V, MCL1 Gain: 4 grades optional Sweep speed: 3 grades optional Leakage of current: Less than 3μA Safety: Endurance of voltage of 4000VAC/50Hz, Defibrillation protection and contra Electrotome interface Indication for electrode cast: Yes Work mode: Diagnosis, monitor, and surgery Alarm indication: Audible and visual, and can be reviewed ST segment monitor: Yes, and alarm range Can be set. Heart rate Measuring range: 25 to 250 bpm Accuracy: +/-2 bmp Tendency chart: 1~24 hours Refurbishing rate: Once for each beat Alarm range: Sustained adjustment of upper and lower Limit between 20~250 Respiration Measuring range: 1~99 bmp Measuring error: +/-2bmp Measuring method: RA-LL Impedance Display: Waveform, respiratory rate Alarm: Yes Alarm range: Adjustable SpO2: Measuring range: 0~100% Accuracy: 80~100%: +/-2%, 60~79%: +/-3%, and have no Requirements when less than 60% Sensor type: Double wavelength LBD Resolution: +/-1% Alarm range: Sustained adjustment of upper and lower Limit between 1~100% Alarm indication: Audible and visual Pulse rate monitor: Yes Pulse rate range: 0~255bmp Non-invasive pulse pressure: Pulse rate range: Automatic vibration Work mode: Automatic/manual Measuring parameters: SYST/DIAS/MEAN/PR Measuring mode: Adult, pediatric, infant Unit: MmHg or kPa Excess pressure safety: Double safe guard Alarm range: 25~240 mmHg adjustable More Product Features Trademark: Perlong Model NO.: PDJ-3000A Standard: GB9706.1 Origin: China Company: Putian Medical Equipment Co., Ltd.
Inquiry About Patient Monitor (PDJ-3000A)* is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: Putian Medical Equipment Co.,Ltd
Area: China/Jiangsu
Contact: Mr. Leo Ma(Foreign Trade D
Tel: 86-25-86452356
Fax: N/A
Web site:
Add: Room 2602, JingLun Building, No. 122, Hanzhong Road, Nanjing, Jiangsu, China
Zip: 210012

Supplier's information
   Putian Medical Equipment Co.,Ltd

     We are the leading manufactory of medical equipment in China. We have six factory to produce di ..... more >>

Contact: Mr. Leo Ma(Foreign Trade D 

(I want to be a Gold Supplier>>)

Other products from this supplier

>>More

View the similar products

>>Search More