Fingertip Pulse Oximeter (AH-50E)

Fingertip Pulse Oximeter (AH-50E)
  • Product Detials:Function:
    Ultra-thin design, concise fashion
    Low power alarm, probe-off alarm, overrun alarm adjustable.
    Inner flash memory for 24 hours storage, and upload to PC.
    The display direction can be changed automatically, easy to view.
    PI detection: Blood stream perfusion index.
    Fingertip oximeter pulse oximeter is a portable oxygen and pulse rate detection equipment, applies to health care sites, families, Oxygen Bar and medical institutions for oxygen and pulse rate detection.

    The main features are as follows:
    SpO2 value display
    1. Pulse rate value display, bar graph display
    2. Pulse waveform display
    3. Perfusion Index value display
    4. Charge function: Lithium battery is the power supply and can be charged up time and again.
    5. Low-power indication: Low-power indication symbol appears before working abnormally which is due to low-power.
    6. Automatic power-off when there is no finger in device under measure interface in 5 seconds.
    7. With direction sensor, the display direction can be changed by automatic or manual mode
    8. Screen brightness can be adjusted
    9. Pulse sound indication
    10. With alarm function
    11. With SpO2 value and pulse rate value record function
    12. The record data can be uploaded to the computer
    13. It can be connected with oximeter probe

    Display:
    Type: 65K color OLED display
    Parameters: SpO2, PR, PI, Pulse bar
    Mode: 4 display modes
    Brightness: Adjustable 4 levels
    Technical specifications
    Measurement of SpO2
    Measuring range: 0% to100%
    Accuracy: When the SpO2 measuring range is 70% to 100%, the permission of absolute error is ± 2Below 70% unspecified
    Measurement of pulse rate
    Measuring range: 30bpm TO 250bpm
    Accuracy: ± 2 bpm or ± 2% (select larger)

    Resolution:
    SpO2: 1%, Pulse rate: 1bpm.
    Measurement Performance in Weak Filling Condition
    SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%, pulse rate error is ± 2 bpm or ± 2% (select larger).
    Resistance to surrounding light
    The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%.

    Storage Environment:
    A) Temperature: -40+60
    B) Relative humidity: 5%-95%
    C) Atmospheric pressure: 500hPa-1060hPa

    Operating Environment:
    A) Temperature: 10C-40C
    B) Relative Humidity: 30%-75%
    C) Atmospheric pressure: 700hPa to 1060hPa
    Dimensions: 58(L) × 36(W) × 26(H) mm
    Weight: About 45g (with a lithium battery)
    Battery RequirementVoltage 3.7 rechargeable lithium battery
    Power supply requirement: : 3.6 V DC ~ 4.2V DC.
Inquiry About Fingertip Pulse Oximeter (AH-50E)* is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: Shenzhen Huge Industry Limited
Area: China/Guangdong
Contact: Mr. Jed Zhang(Sales Depart
Tel: 86-755-61390018
Fax: 86-755-61390017
Web site: http://www.healthcare-ems.com
Add: No. 10 Blg, Donghai Technology park, Dakang Futian Villiage, Henggang, Longgang, Shenzhen, Guangdong, China
Zip: 518115

Supplier's information
   Shenzhen Huge Industry Limited

     Shenzhen huge industry limited is the subsidiary company of Shenzhen Golden Sunrise Plastic Mol ..... more >>

Contact: Mr. Jed Zhang(Sales Depart 

(I want to be a Gold Supplier>>)

Other products from this supplier

>>More

View the similar products

>>Search More