Tissue Processor (ATP700)

Tissue Processor (ATP700)
  • Product Detials:Characteristics:
    Protection from getting stuck: If the hanging basket comes into contact with any obstacles when entering the liguid tank during operation, it will returm to the first tand so as to ptotect the tissue from being destroyed.
    Self-adapted cover used with the multiple gasket seal prodeces excellent sealing performance, which minimizes the volatilization loss of the liguid.
    The organic glass cover, sealing strips and double layer actibe carbon filter ensure that the air in the room is not polluted.
    The large screen LCD shows the operating conditions clearly.
    Manual operation can be used at will during running to abjust the processing time
    Electromagnetism can move the basket according to program you have set to enter the next tank
    ATP700 can move two baskets at the same time. The two baskets execute different programs to meet the requirement the dewatering kinds of tissue. The dewa tereris at present a new product original in the world.
    Protection functions for power failure
    The basket will enter into liquid tank as the Power failure, and shall continue to operate as the original process until power-on.
    ATP700 Tissue processor can also be provided to ensure that the program is completely executed without in terrcuption under the power status of power failure

    Technical Parameters:
    Guantity of liguid tank: 10 reagent tanks and 4 wax tanks
    Dimension of liquid tank: 1300ml, can be set 144 standard cassettes
    Guantitg of being process in same time: 144 Standard cassettes
    Retention time in each tank: 1 minute~99 hours and 59 minutes
    Retention tine after leaving the tank: 30 seconds
    Temperature range: Room temperature----99centigrade
    Temperature tolerance: The temperature error within one centigrade
    The two baskets move up and downin turn every 5 minutes
    Power supply: 220V(up or down 10%)50Hz or 110V(up or down 10%) 50/60Hz
    Power: 450W
    Outside dimensions(mm): 1200*530*590
    Weight: 105kg
Inquiry About Tissue Processor (ATP700) * is required.
 
Subject: *
Message: *
 
Company Name: *
Your Name: *
Business Phone: *
(Type: +86-571-88228426)
Fax:
Business Email: *
Zip:
Address:
CheckCode:      *

         
Contact Info
Company: Changzhou Haosilin Medical Instrument Co.,Ltd
Area: China/Jiangsu
Contact: Miss Tracy Feng(International
Tel: 86-519-85125282
Fax: 86-519-85607990
Web site: http://www.histo-instrument.com
Add: 501, Bei Cheng Hou Street, Taihu Rd, New North District, Changzhou, Jiangsu, China
Zip: 213002

Supplier's information
   Changzhou Haosilin Medical Instrument Co.,Ltd

     Changzhou Haosilin Medical Instrument Co., Ltd., was established in 1998. It has been engaged i ..... more >>

Contact: Miss Tracy Feng(International  

(I want to be a Gold Supplier>>)

Other products from this supplier

>>More

View the similar products

>>Search More