Gas Chromatograph (GC9790I)
- Product Name:
Gas Chromatograph (GC9790I)
- Category: Others
- Package: Carton
- Price: Get Latest Price
- Product Detials:
Gas Chromatograph (GC9790I)
Capillary and packed column inlets, split and splitless, cool-on-column
Programmable oven, max 5 rates, 6 temperatures, up to 400ºC
Wide dynamic range of popular detectors: FID, TCD, NPD, ECD and FPD
Instrument control, method setup and run from keyboard entries
Rugged manual injection and manual pneumatics
Self-diagnosis of controls: thermal zone, flows, and detectors
Ready to use when product delivered and installed
Unbeatable price and service package
Guarantee timely and no-hassle service responding
Technical Parameter for GC9790Series
Dimension (cm)
55(L)×48(W)×49(H)
Approximate weight (kg)
50
Power
90240Vac, 5060Hz, 2.0Kw
Environmental condition
1050ºC, humidity <85%
Intuitive instrument control
Panel keypad input, 10 methods in memory
Display
5 lines LED
Injection
2 manual injectors, split/splitless, cool-on-column, valve injection. Max temperature 399ºC
Oven volume
14.6liters
Column oven
26(L)×15(W)×25(H)
Oven
40ºC400ºC, ±0.1ºC. 5 rates, 6 temperature settings
No. of temperature zones
5, inlet, oven, detector, aux 1, aux 2
Max temperature rise rate
40ºC/min
Pneumatics
Manual control; Max pressure 10bar; Max column flow 50ml/min
Gas purifications
In-line traps, O2, moistures, hydrocarbons, CO/CO2
FID Detector
Max temperature
399ºC
Column
Capillary or packed columns
Sensitivity
<1×10-11g/s
Dynamic linear range
>106
Base line rise
<5×10-13A/30min
Noise
5×10-14 A
Signal output
1μV1000mV
FPD Detector
Max temperature
399ºC
Column
Capillary or packed columns
Sensitivity
<1.4×10-12 g/s (P), <5×10-11 g/s (S)
Dynamic linear range
>103 (P), >102(S)
Base line rise
<4×10-10g/s /30min
Noise
<4×10-10 g/s
Signal output
1μV1000mV
TCD Detector
Max temperature
399ºC
Column
Capillary or packed columns
Sensitivity
>2500mV ml/mg
Dynamic linear range
>104
Base line rise
<100μV/30min
Noise
<20μV
Signal output
1μV1000mV
ECD Detector
Max temperature
399ºC
Column
Capillary or packed columns
Sensitivity
<1×10-13 g/ml
Dynamic linear range
>104
Base line rise
<50μV/30min
Noise
<20μV
Signal output
1μV1000mV
Detector: NPD
Specifications for GC9790SeriesMax temperature
399ºC
Column
Capillary or packed columns
Sensitivity
<5×10-13 g/s (N), <5×10-12 g/s (P)
Dynamic linear range
>103
Base line rise
<4×10-10g/s /30min
Noise
<4×10-10 g/s
Signal output
1μV1000mV
MODEL
SPECIFICATION
Dual packed column
GC9790F
Dual FID Detector
GC9790T
TCD Detector
GC9790T-2
TCD Detector, amplified board (high sensitivity)
GC9790P
FPD Detector
GC9790E
ECD Detector
GC9790G
Dual FID Detector, dual FID amplified board (high sensitivity)
GC9790B
Dual FID Detector, TCD Detector
GC9790D
FID Detector, FPD Detector
GC9790K
Dual FID Detector, ECD Detector
GC9790H
TCD Detector, FPD Detector
GC9790L-3
FID Detector, ECD Detector, FPD Detector
Capillary column inlet, Packed column inlet
GC9790J
Dual FID Detector
GC9790R
Dual FID Detector, NPD Detector
GC9790C
Dual FID Detector, dual FID amplified board
GC9790A
Dual FID Detector, TCD Detector
GC9790I
FID Detector, FPD Detector
GC9790L
Dual FID Detector, ECD Detector
GC9790L-2
FID Detector, ECD Detector, FPD Detector
GC9790Q
Dual FID Detector, ECD Detector
GC9790N
Dual FID Detector, ECD Detector
- Inquiry About Gas Chromatograph (GC9790I)* is required.
- Contact Info
-
Company: Tsingtao Unicom-Optics Instruments Co.,Ltd Area: China/Shandong Contact: Mr. Domty Tel: 86-532-88480588 Fax: 86-532-88480587 Web site: www.unicomoptics.com Add: Building 2, Huanghai West Road, Laixi City, Qingdao, Shandong, China Zip: 266600
- Supplier's information
-
Tsingtao Unicom-Optics Instruments Co.,Ltd
Tsingtao Unicom-Optics Instruments Co., Ltd. Tsingtao Unicom-Optics Instrumen ..... more >>
- View the similar products
-